Remote-only monitoring for patients with cardiac implantable electronic devices: a before-and-after pilot study.


ABSTRACT:

Background

Outcomes for patients with cardiac implantable electronic devices are better when follow-up incorporates remote monitoring technology in addition to in-clinic visits. For patients with implantable devices, we sought to determine the feasibility, safety and associated health care utilization of remote-only follow-up, along with its effects on patients' quality of life and costs.

Methods

This multicentre before-and-after pilot study involved patients with new or existing pacemakers or implantable cardioverter defibrillators. The "before" phase of the study spanned the period October 2015 to February 2017; the "after" phase spanned the period October 2016 to February 2018. The exposure was remote-only follow-up in combination with Remote View, a service that facilitates access to device data, allowing device settings to be viewed remotely to facilitate remote programming. Outcomes at 12 months were feasibility (adherence to remote monitoring), safety (rate of adverse events) and health care utilization (remote and in-clinic appointments). We also assessed quality of life, using 3 validated scales, and costs, taking into account both health care system and patient costs.

Results

A total of 176 patients were enrolled. Adherence (defined as at least 1 successful remote transmission during follow-up) was 87% over a mean follow-up of 11.7 (standard deviation 2.2) months. There was a reduction in in-clinic visits at specialized sites among patients with both implantable defibrillators (26 v. 5, p < 0.001, n = 48) and pacemakers (42 v. 10, p < 0.001, n = 51). There was no significant change in visits to community sites for patients with defibrillators (13 v. 17, p = 0.3, n = 48). The composite rate of death, stroke, cardiovascular hospitalization and device-related hospitalization was 7% (n = 164). No adverse events were linked to the intervention. There was no change in quality-of-life scales between baseline and 12 months. Health care costs were reduced by 31% for patients with defibrillators and by 44% for those with pacemakers.

Interpretation

This pilot study showed the feasibility of remote-only follow-up, with no increase in adverse clinical outcomes and no effect on quality of life, but with reductions in costs and health care utilization. These results support progression to a larger-scale study of whether superior effectiveness and reduced cost can be achieved, with preservation of safety, through use of remote-only follow-up.

Trial registration

ClinicalTrials.gov, no. NCT02585817.

SUBMITTER: Sapp JA 

PROVIDER: S-EPMC7843075 | biostudies-literature | 2021 Jan-Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Background</h4>Outcomes for patients with cardiac implantable electronic devices are better when follow-up incorporates remote monitoring technology in addition to in-clinic visits. For patients with implantable devices, we sought to determine the feasibility, safety and associated health care utilization of remote-only follow-up, along with its effects on patients' quality of life and costs.<h4>Methods</h4>This multicentre before-and-after pilot study involved patients with new or existing  ...[more]

Similar Datasets

| S-EPMC7183665 | biostudies-literature
| S-EPMC10017432 | biostudies-literature
| S-EPMC10219157 | biostudies-literature
| S-EPMC10522456 | biostudies-literature
| S-EPMC8129436 | biostudies-literature
| S-EPMC9890086 | biostudies-literature
| S-EPMC5135181 | biostudies-other
| S-EPMC6938593 | biostudies-literature
| S-EPMC6436519 | biostudies-literature
| S-EPMC5837548 | biostudies-literature