Unknown

Dataset Information

0

Modified Delta-shaped Anastomosis via the Overlap Method Using Linear Staplers for Colon Cancer.


ABSTRACT: Here, we describe the modified delta-shaped anastomosis (DSA) via the overlap method and how it was a beneficial intracorporeal anastomotic technique for four patients who underwent laparoscopic colectomy. After resecting the colon on both sides of the lesion, proximal and distal colon were laid in an overlap fashion and fixed using sutures. The entry hole was created using an ultrasound scalpel at a point 3 cm proximal to right colic stump and 7 cm distal to left colic stump on the anti-mesenteric side. Then, two arms of the linear stapler were inserted inside each lumen and fired. Finally, using the linear stapler, the common entry hole was closed in a delta-shaped manner. The mean duration of surgery was determined to be 218.4 (196-369) minutes, and amount of blood loss was measured to be 11 (5-25) mL. No intraoperative and postoperative complications were observed. Median postoperative hospital stay was 12 days. Thus, modified DSA via overlap method can be considered as a safe and simple IA technique.

SUBMITTER: Nepal P 

PROVIDER: S-EPMC7843145 | biostudies-literature | 2021

REPOSITORIES: biostudies-literature

altmetric image

Publications

Modified Delta-shaped Anastomosis via the Overlap Method Using Linear Staplers for Colon Cancer.

Nepal Pramod P   Mori Shinichiro S   Kita Yoshiaki Y   Tanabe Kan K   Baba Kenji K   Sasaki Ken K   Kurahara Hiroshi H   Arigami Takaaki T   Maemura Kosei K   Ohtsuka Takao T   Natsugoe Shoji S  

Journal of the anus, rectum and colon 20210128 1


Here, we describe the modified delta-shaped anastomosis (DSA) via the overlap method and how it was a beneficial intracorporeal anastomotic technique for four patients who underwent laparoscopic colectomy. After resecting the colon on both sides of the lesion, proximal and distal colon were laid in an overlap fashion and fixed using sutures. The entry hole was created using an ultrasound scalpel at a point 3 cm proximal to right colic stump and 7 cm distal to left colic stump on the anti-mesente  ...[more]

Similar Datasets

| S-EPMC8016753 | biostudies-literature
| S-EPMC7376961 | biostudies-literature
| S-EPMC7477196 | biostudies-literature
| S-EPMC7059953 | biostudies-literature
| S-EPMC7529547 | biostudies-literature
| S-EPMC5455638 | biostudies-literature
| S-EPMC8501210 | biostudies-literature
| S-EPMC10442086 | biostudies-literature
| S-EPMC9271030 | biostudies-literature