Unknown

Dataset Information

0

An integrated set-up for ex vivo characterisation of biaxial murine artery biomechanics under pulsatile conditions.


ABSTRACT: Ex vivo characterisation of arterial biomechanics enables detailed discrimination of the various cellular and extracellular contributions to arterial stiffness. However, ex vivo biomechanical studies are commonly performed under quasi-static conditions, whereas dynamic biomechanical behaviour (as relevant in vivo) may differ substantially. Hence, we aim to (1) develop an integrated set-up for quasi-static and dynamic biaxial biomechanical testing, (2) quantify set-up reproducibility, and (3) illustrate the differences in measured arterial stiffness between quasi-static and dynamic conditions. Twenty-two mouse carotid arteries were mounted between glass micropipettes and kept fully vasodilated. While recording pressure, axial force (F), and inner diameter, arteries were exposed to (1) quasi-static pressure inflation from 0 to 200 mmHg; (2) 300 bpm dynamic pressure inflation (peaking at 80/120/160 mmHg); and (3) axial stretch (?z) variation at constant pressures of 10/60/100/140/200 mmHg. Measurements were performed in duplicate. Single-point pulse wave velocities (PWV; Bramwell-Hill) and axial stiffness coefficients (cax?=?dF/d?z) were calculated at the in vivo value of ?z. Within-subject coefficients of variation were?~?20%. Dynamic PWVs were consistently higher than quasi-static PWVs (p?ax increased with increasing pressure. We demonstrated the feasibility of ex vivo biomechanical characterisation of biaxially-loaded murine carotid arteries under pulsatile conditions, and quantified reproducibility allowing for well-powered future study design.

SUBMITTER: van der Bruggen MM 

PROVIDER: S-EPMC7846753 | biostudies-literature | 2021 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

An integrated set-up for ex vivo characterisation of biaxial murine artery biomechanics under pulsatile conditions.

van der Bruggen Myrthe M MM   Reesink Koen D KD   Spronck Paul J M PJM   Bitsch Nicole N   Hameleers Jeroen J   Megens Remco T A RTA   Schalkwijk Casper G CG   Delhaas Tammo T   Spronck Bart B  

Scientific reports 20210129 1


Ex vivo characterisation of arterial biomechanics enables detailed discrimination of the various cellular and extracellular contributions to arterial stiffness. However, ex vivo biomechanical studies are commonly performed under quasi-static conditions, whereas dynamic biomechanical behaviour (as relevant in vivo) may differ substantially. Hence, we aim to (1) develop an integrated set-up for quasi-static and dynamic biaxial biomechanical testing, (2) quantify set-up reproducibility, and (3) ill  ...[more]

Similar Datasets

| S-EPMC3148203 | biostudies-literature
| S-EPMC8899021 | biostudies-literature
| S-EPMC8111436 | biostudies-literature
| S-EPMC8569808 | biostudies-literature
| S-EPMC6298538 | biostudies-literature
| S-EPMC5458827 | biostudies-other
| S-EPMC7018024 | biostudies-literature
| S-EPMC8032640 | biostudies-literature
| S-EPMC7219311 | biostudies-literature