Project description:Video 1Placing a standard endoclip at the papillary side of a duodenal perforation is a simple and effective technique for prevention of papillary obstruction when using the over-the-scope clip.
Project description:Endoscopic ultrasonography (EUS) and endoscopic retrograde cholangiopancreatography (ERCP) for pancreatobiliary diseases require advanced techniques. We usually use an oblique-viewing endoscope in such procedures. Sometimes, tumor invasion causes gastrointestinal strictures. Crossing a stricture using an oblique-viewing endoscope is more difficult than using a forward-viewing scope. Therefore, the frequency of scope perforation is higher than other endoscopic procedures. Although surgical repair for gastrointestinal perforations caused by endoscopes has been performed, patients with pancreatobiliary diseases are often elderly and in poor general condition; therefore, patients are hesitant to undergo surgical treatments. Recently, the usefulness of over-the-scope clipping (OTSC) as a minimally invasive rescue method has also been reported. In this study, we report cases of successful endoscopic closure using OTSC for gastrointestinal perforations caused by endoscopes in ERCP and EUS-related procedures. After those procedures, all cases showed no abnormalities in blood tests or symptoms, and emergency surgery was successfully avoided. Thus, endoscopic closure using OTSC for pancreatobiliary endoscopy-related gastrointestinal perforations is safe and effective. However, OTSC requires some expertise. A good assessment of defect size and careful insertion of the scope using OTSC attached to the upper esophagus are needed to avoid clip migration or disinsertion and esophageal tears. Therefore, endoscopic closure using OTSC could be the first choice of treatment for pancreatobiliary endoscopy-related gastrointestinal perforations. We should be familiar with its indication and perform it carefully and rapidly.
Project description:ObjectivesRecently, a novel clip device, SureClip® (Micro-Tech Co. Ltd., Nanjing, China), has been developed, which improved rotation and reopening performance. We aimed to assess the efficacy of the SureClip® in prophylactic closure of the mucosal break after endoscopic papillectomy (EP) for ampullary neoplasm.MethodsWe retrospectively reviewed the medical records of 40 patients who underwent EP for ampullary neoplasms between October 2009 and March 2020. Prophylactic closure after resection was performed using the conventional clip between 2014 and 2018, and with the SureClip® after 2019. The baseline characteristics, techniques, outcomes, and complications of EP were analyzed.ResultsThe median age of the patients (25 males and 15 females) was 70 years. The en block resection rate was 82.5% and the curative resection rate was 80.0%. Histologically, 11 (27.5%) patients had malignancy. Prophylactic closure was performed in 29 (72.5%) patients (17 conventional clips, 12 SureClip®). Complications occurred in 18 (45.0%) patients, including postprocedure bleeding in 9 (22.5%) patients. However, no postprocedure bleeding was observed in the patients who received prophylactic closure using the SureClip® (p = 0.038). All other factors were not significantly correlated with postprocedure bleeding. The duration of hospital stay after EP was significantly shorter in patients treated with the SureClip® compared to those treated with a conventional clip or without clips (p < 0.05).ConclusionsIn the present study, prophylactic clipping of the mucosal break using the SureClip® was effective in preventing bleeding after EP.
Project description:Endoscopic treatment for superficial non-ampullary duodenal tumors is technically difficult and challenging due to the anatomical characteristics of the duodenum. It is frequently complicated by procedural accidents, such as perforation. Surgical repair has long been the standard treatment for acute iatrogenic gastrointestinal perforation. However, endoscopic closure has recently emerged as an attractive alternative. In the patient presented herein, the over-the-scope-clipping system (OTSC system) was found to be useful for closing a duodenal perforation that had occurred during endoscopic submucosal dissection. For endoscopists who perform endoscopic treatment of the duodenum, endoscopic closure with the OTSC system is considered to be a technique that is necessary to master.
Project description:Video 1Endoscopic closure of an iatrogenic perforation caused during EUS-guided gastrojejunostomy for malignant gastric outlet obstruction treated with an over-the-scope stent fixation clip device.