Unknown

Dataset Information

0

Identification of robust and reproducible CT-texture metrics using a customized 3D-printed texture phantom.


ABSTRACT:

Objective

The objective of this study was to evaluate the robustness and reproducibility of computed tomography-based texture analysis (CTTA) metrics extracted from CT images of a customized texture phantom built for assessing the association of texture metrics to three-dimensional (3D) printed progressively increasing textural heterogeneity.

Materials and methods

A custom-built 3D-printed texture phantom comprising of six texture patterns was used to evaluate the robustness and reproducibility of a radiomics panel under a variety of routine abdominal imaging protocols. The phantom was scanned on four CT scanners (Philips, Canon, GE, and Siemens) to assess reproducibility. The robustness assessment was conducted by imaging the texture phantom across different CT imaging parameters such as slice thickness, field of view (FOV), tube voltage, and tube current for each scanner. The texture panel comprised of 387 features belonging to 15 subgroups of texture extraction methods (e.g., Gray-level Co-occurrence Matrix: GLCM). Twelve unique image settings were tested on all the four scanners (e.g., FOV125). Interclass correlation two-way mixed with absolute agreement (ICC3) was used to assess the robustness and reproducibility of radiomic features. Linear regression was used to test the association between change in radiomic features and increased texture heterogeneity. Results were summarized in heat maps.

Results

A total of 5612 (23.2%) of 24 090 features showed excellent robustness and reproducibility (ICC ? 0.9). Intensity, GLCM 3D, and gray-level run length matrix (GLRLM) 3D features showed best performance. Among imaging variables, changes in slice thickness affected all metrics more intensely compared to other imaging variables in reducing the ICC3. From the analysis of linear trend effect of the CTTA metrics, the top three metrics with high linear correlations across all scanners and scanning settings were from the GLRLM 2D/3D and discrete cosine transform (DCT) texture family.

Conclusion

The choice of scanner and imaging protocols affect texture metrics. Furthermore, not all CTTA metrics have a linear association with linearly varying texture patterns.

SUBMITTER: Varghese BA 

PROVIDER: S-EPMC7882093 | biostudies-literature | 2021 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Identification of robust and reproducible CT-texture metrics using a customized 3D-printed texture phantom.

Varghese Bino A BA   Hwang Darryl D   Cen Steven Y SY   Lei Xiaomeng X   Levy Joshua J   Desai Bhushan B   Goodenough David J DJ   Duddalwar Vinay A VA  

Journal of applied clinical medical physics 20210112 2


<h4>Objective</h4>The objective of this study was to evaluate the robustness and reproducibility of computed tomography-based texture analysis (CTTA) metrics extracted from CT images of a customized texture phantom built for assessing the association of texture metrics to three-dimensional (3D) printed progressively increasing textural heterogeneity.<h4>Materials and methods</h4>A custom-built 3D-printed texture phantom comprising of six texture patterns was used to evaluate the robustness and r  ...[more]

Similar Datasets

| S-EPMC6698768 | biostudies-literature
| S-EPMC6595118 | biostudies-literature
| S-EPMC7063285 | biostudies-literature
| S-EPMC5689973 | biostudies-literature
| S-EPMC8596689 | biostudies-literature
| S-EPMC6376205 | biostudies-literature
| S-EPMC5768004 | biostudies-literature
| S-EPMC9260230 | biostudies-literature
| S-EPMC9205921 | biostudies-literature
| S-EPMC5357966 | biostudies-literature