Ontology highlight
ABSTRACT: Objectives
To assess whether vessel morphology depicted by three-dimensional (3D) power Doppler ultrasound improves discrimination between benignity and malignancy if used as a second-stage test in adnexal masses that are difficult to classify.Methods
This was a prospective observational international multicenter diagnostic accuracy study. Consecutive patients with an adnexal mass underwent standardized transvaginal two-dimensional (2D) grayscale and color or power Doppler and 3D power Doppler ultrasound examination by an experienced examiner, and those with a 'difficult' tumor were included in the current analysis. A difficult tumor was defined as one in which the International Ovarian Tumor Analysis (IOTA) logistic regression model-1 (LR-1) yielded an ambiguous result (risk of malignancy, 8.3% to 25.5%), or as one in which the ultrasound examiner was uncertain regarding classification as benign or malignant when using subjective assessment. Even when the ultrasound examiner was uncertain, he/she was obliged to classify the tumor as most probably benign or most probably malignant. For each difficult tumor, one researcher created a 360° rotating 3D power Doppler image of the vessel tree in the whole tumor and another of the vessel tree in a 5-cm3 spherical volume selected from the most vascularized part of the tumor. Two other researchers, blinded to the patient's history, 2D ultrasound findings and histological diagnosis, independently described the vessel tree using predetermined vessel features. Their agreed classification was used. The reference standard was the histological diagnosis of the mass. The sensitivity of each test for discriminating between benign and malignant difficult tumors was plotted against 1?-?specificity on a receiver-operating-characteristics diagram, and the test with the point furthest from the reference line was considered to have the best diagnostic ability.Results
Of 2403 women with an adnexal mass, 376 (16%) had a difficult mass. Ultrasound volumes were available for 138 of these cases. In 79/138 masses, the ultrasound examiner was uncertain about the diagnosis based on subjective assessment, in 87/138, IOTA LR-1 yielded an ambiguous result and, in 28/138, both methods gave an uncertain result. Of the masses, 38/138 (28%) were malignant. Among tumors that were difficult to classify as benign or malignant by subjective assessment, the vessel feature 'densely packed vessels' had the best discriminative ability (sensitivity 67% (18/27), specificity 83% (43/52)) and was slightly superior to subjective assessment (sensitivity 74% (20/27), specificity 60% (31/52)). In tumors in which IOTA LR-1 yielded an ambiguous result, subjective assessment (sensitivity 82% (14/17), specificity 79% (55/70)) was superior to the best vascular feature, i.e. changes in the diameter of vessels in the whole tumor volume (sensitivity 71% (12/17), specificity 69% (48/70)).Conclusion
Vessel morphology depicted by 3D power Doppler ultrasound may slightly improve discrimination between benign and malignant adnexal tumors that are difficult to classify by subjective ultrasound assessment. For tumors in which the IOTA LR-1 model yields an ambiguous result, subjective assessment is superior to vessel morphology as a second-stage test. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
SUBMITTER: Sladkevicius P
PROVIDER: S-EPMC7898332 | biostudies-literature | 2021 Feb
REPOSITORIES: biostudies-literature
Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology 20210201 2
<h4>Objectives</h4>To assess whether vessel morphology depicted by three-dimensional (3D) power Doppler ultrasound improves discrimination between benignity and malignancy if used as a second-stage test in adnexal masses that are difficult to classify.<h4>Methods</h4>This was a prospective observational international multicenter diagnostic accuracy study. Consecutive patients with an adnexal mass underwent standardized transvaginal two-dimensional (2D) grayscale and color or power Doppler and 3D ...[more]