Use of Mechanical Circulatory Support Devices Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock.


ABSTRACT:

Importance

Mechanical circulatory support (MCS) devices, including intravascular microaxial left ventricular assist devices (LVADs) and intra-aortic balloon pumps (IABPs), are used in patients who undergo percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) complicated by cardiogenic shock despite limited evidence of their clinical benefit.

Objective

To examine trends in the use of MCS devices among patients who underwent PCI for AMI with cardiogenic shock, hospital-level use variation, and factors associated with use.

Design, setting, and participants

This cross-sectional study used the CathPCI and Chest Pain-MI Registries of the American College of Cardiology National Cardiovascular Data Registry. Patients who underwent PCI for AMI complicated by cardiogenic shock between October 1, 2015, and December 31, 2017, were identified from both registries. Data were analyzed from October 2018 to August 2020.

Exposures

Therapies to provide hemodynamic support were categorized as intravascular microaxial LVAD, IABP, TandemHeart, extracorporeal membrane oxygenation, LVAD, other devices, combined IABP and intravascular microaxial LVAD, combined IABP and other device (defined as TandemHeart, extracorporeal membrane oxygenation, LVAD, or another MCS device), or medical therapy only.

Main outcomes and measures

Use of MCS devices overall and specific MCS devices, including intravascular microaxial LVAD, at both patient and hospital levels and variables associated with use.

Results

Among the 28?304 patients included in the study, the mean (SD) age was 65.4 (12.6) years and 18 968 were men (67.0%). The overall MCS device use was constant from the fourth quarter of 2015 to the fourth quarter of 2017, although use of intravascular microaxial LVADs significantly increased (from 4.1% to 9.8%; P?Conclusions and relevanceThis study found that, among patients who underwent PCI for AMI complicated by cardiogenic shock, overall use of MCS devices was constant, and a 2.5-fold increase in intravascular microaxial LVAD use was found along with a corresponding decrease in IABP use and a significant hospital-level variation in MCS device use. These trends were observed despite limited clinical trial evidence of improved outcomes associated with device use.

SUBMITTER: Dhruva SS 

PROVIDER: S-EPMC7900859 | biostudies-literature | 2021 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Importance</h4>Mechanical circulatory support (MCS) devices, including intravascular microaxial left ventricular assist devices (LVADs) and intra-aortic balloon pumps (IABPs), are used in patients who undergo percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) complicated by cardiogenic shock despite limited evidence of their clinical benefit.<h4>Objective</h4>To examine trends in the use of MCS devices among patients who underwent PCI for AMI with cardiogenic shoc  ...[more]

Similar Datasets

| S-EPMC8772168 | biostudies-literature
| S-EPMC5640487 | biostudies-literature
| S-EPMC6424352 | biostudies-literature
| S-EPMC5650570 | biostudies-other
| S-EPMC7710954 | biostudies-literature
| S-EPMC11307771 | biostudies-literature
| S-EPMC4191250 | biostudies-literature
| S-EPMC7356113 | biostudies-literature
| S-EPMC8037539 | biostudies-literature
| S-EPMC8006704 | biostudies-literature