Unknown

Dataset Information

0

Is the 1-Minute Sit-To-Stand Test a Good Tool to Evaluate Exertional Oxygen Desaturation in Chronic Obstructive Pulmonary Disease?


ABSTRACT: Chronic obstructive pulmonary disease (COPD) is frequently associated with exertional oxygen desaturation, which may be evaluated using the 6-minute walking test (6MWT). However, it is a time-consuming test. The 1-minute sit-to-stand test (1STST) is a simpler test, already used to evaluate the functional status. The aim of this study was to compare the 1STST to the 6MWT in the evaluation of exertional desaturation. This was a cross-sectional study including 30 stable COPD patients who performed the 6MWT and 1STST on the same day. Six-minute walking distance (6MWD), number of 1STST repetitions (1STSTr), and cardiorespiratory parameters were recorded. A significant correlation was found between the 6MWD and the number of 1STSTr (r = 0.54; p = 0.002). The minimum oxygen saturation (SpO2) in both tests showed a good agreement (intraclass correlation coefficient (ICC) 0.81) and correlated strongly (r = 0.84; p < 0.001). Regarding oxygen desaturation, the total agreement between the tests was 73.3% with a fair Cohen´s kappa (κ = 0.38; p = 0.018), and 93.33% of observations were within the limits of agreement for both tests in the Bland-Altman analysis. The 1STST seems to be a capable tool of detecting exercise-induced oxygen desaturation in COPD. Because it is a less time- and resources-consuming test, it may be applied during the outpatient clinic consultation to regularly evaluate the exercise capacity and exertional desaturation in COPD.

SUBMITTER: Fernandes AL 

PROVIDER: S-EPMC7911810 | biostudies-literature | 2021 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Is the 1-Minute Sit-To-Stand Test a Good Tool to Evaluate Exertional Oxygen Desaturation in Chronic Obstructive Pulmonary Disease?

Fernandes Ana L AL   Neves Inês I   Luís Graciete G   Camilo Zita Z   Cabrita Bruno B   Dias Sara S   Ferreira Jorge J   Simão Paula P  

Diagnostics (Basel, Switzerland) 20210122 2


<h4>Background</h4>Chronic obstructive pulmonary disease (COPD) is frequently associated with exertional oxygen desaturation, which may be evaluated using the 6-minute walking test (6MWT). However, it is a time-consuming test. The 1-minute sit-to-stand test (1STST) is a simpler test, already used to evaluate the functional status. The aim of this study was to compare the 1STST to the 6MWT in the evaluation of exertional desaturation.<h4>Methods</h4>This was a cross-sectional study including 30 s  ...[more]

Similar Datasets

| S-EPMC8795411 | biostudies-literature
| S-EPMC7923980 | biostudies-literature
| S-EPMC10015133 | biostudies-literature
| S-EPMC9508743 | biostudies-literature
| S-EPMC8130592 | biostudies-literature
| S-EPMC9997887 | biostudies-literature
| S-EPMC8970334 | biostudies-literature
| S-EPMC8968777 | biostudies-literature
| S-EPMC3922802 | biostudies-literature
| S-EPMC8108674 | biostudies-literature