Is the 1-Minute Sit-To-Stand Test a Good Tool to Evaluate Exertional Oxygen Desaturation in Chronic Obstructive Pulmonary Disease?


ABSTRACT:

Background

Chronic obstructive pulmonary disease (COPD) is frequently associated with exertional oxygen desaturation, which may be evaluated using the 6-minute walking test (6MWT). However, it is a time-consuming test. The 1-minute sit-to-stand test (1STST) is a simpler test, already used to evaluate the functional status. The aim of this study was to compare the 1STST to the 6MWT in the evaluation of exertional desaturation.

Methods

This was a cross-sectional study including 30 stable COPD patients who performed the 6MWT and 1STST on the same day. Six-minute walking distance (6MWD), number of 1STST repetitions (1STSTr), and cardiorespiratory parameters were recorded.

Results

A significant correlation was found between the 6MWD and the number of 1STSTr (r = 0.54; p = 0.002). The minimum oxygen saturation (SpO2) in both tests showed a good agreement (intraclass correlation coefficient (ICC) 0.81) and correlated strongly (r = 0.84; p < 0.001). Regarding oxygen desaturation, the total agreement between the tests was 73.3% with a fair Cohen´s kappa (? = 0.38; p = 0.018), and 93.33% of observations were within the limits of agreement for both tests in the Bland-Altman analysis.

Conclusion

The 1STST seems to be a capable tool of detecting exercise-induced oxygen desaturation in COPD. Because it is a less time- and resources-consuming test, it may be applied during the outpatient clinic consultation to regularly evaluate the exercise capacity and exertional desaturation in COPD.

SUBMITTER: Fernandes AL 

PROVIDER: S-EPMC7911810 | biostudies-literature | 2021 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Is the 1-Minute Sit-To-Stand Test a Good Tool to Evaluate Exertional Oxygen Desaturation in Chronic Obstructive Pulmonary Disease?

Fernandes Ana L AL   Neves Inês I   Luís Graciete G   Camilo Zita Z   Cabrita Bruno B   Dias Sara S   Ferreira Jorge J   Simão Paula P  

Diagnostics (Basel, Switzerland) 20210122 2


<h4>Background</h4>Chronic obstructive pulmonary disease (COPD) is frequently associated with exertional oxygen desaturation, which may be evaluated using the 6-minute walking test (6MWT). However, it is a time-consuming test. The 1-minute sit-to-stand test (1STST) is a simpler test, already used to evaluate the functional status. The aim of this study was to compare the 1STST to the 6MWT in the evaluation of exertional desaturation.<h4>Methods</h4>This was a cross-sectional study including 30 s  ...[more]

Similar Datasets

| S-EPMC8795411 | biostudies-literature
| S-EPMC7923980 | biostudies-literature
| S-EPMC10015133 | biostudies-literature
| S-EPMC9508743 | biostudies-literature
| S-EPMC8130592 | biostudies-literature
| S-EPMC9997887 | biostudies-literature
| S-EPMC8970334 | biostudies-literature
| S-EPMC8968777 | biostudies-literature
| S-EPMC3922802 | biostudies-literature
| S-EPMC8108674 | biostudies-literature