Unknown

Dataset Information

0

Prognostic Value of Preoperative Echocardiographic Findings in Patients Undergoing Transvenous Lead Extraction.


ABSTRACT: (1) Background: In patients referred for transvenous lead extraction (TLE) transesophageal echocardiography (TEE) often reveals abnormalities related to chronically indwelling endocardial leads. The purpose of this study was to determine whether the results of pre-operative TEE might influence the long-term prognosis. (2) Methods: We analyzed data from 936 TEE examinations performed at a high volume center in patients referred for TLE from 2015 to 2019. The follow-up was 566.2 ± 224.5 days. (3) Results: Multivariate analysis of TEE parameters showed that vegetations (HR = 2.631 [1.738-3.983]; p < 0.001) and tricuspid valve (TV) dysfunction unrelated to the endocardial lead (HR = 1.481 [1.261-1.740]; p < 0.001) were associated with increased risk for long-term mortality. Presence of fibrous tissue binding sites between the lead and the superior vena cava (SVC) and/or right atrium (RA) wall (HR = 0.285; p = 0.035), presence of penetration or perforation of the lead through the cardiac wall up to the epicardium (HR = 0.496; p = 0.035) and presence of excessive lead loops (HR = 0.528; p = 0.026) showed a better prognosis. After adjustment the statistical model with recognized poor prognosis factors only vegetations were confirmed as a risk factor (HR = 2.613; p = 0.039). A better prognosis was observed in patients with fibrous tissue binding sites between the lead and the superior vena cava (SVC) and/or right atrium (RA) wall (HR = 0.270; p = 0.040). (4) Conclusions: Non-modifiable factors may have a negative influence on long-term survival after TLE. Various forms of connective tissue overgrowth and abnormal course of the leads modifiable by TLE can be a factor of better prognosis after TLE.

SUBMITTER: Nowosielecka D 

PROVIDER: S-EPMC7918219 | biostudies-literature | 2021 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Prognostic Value of Preoperative Echocardiographic Findings in Patients Undergoing Transvenous Lead Extraction.

Nowosielecka Dorota D   Jacheć Wojciech W   Polewczyk Anna A   Tułecki Łukasz Ł   Kleinrok Andrzej A   Kutarski Andrzej A  

International journal of environmental research and public health 20210214 4


(1) Background: In patients referred for transvenous lead extraction (TLE) transesophageal echocardiography (TEE) often reveals abnormalities related to chronically indwelling endocardial leads. The purpose of this study was to determine whether the results of pre-operative TEE might influence the long-term prognosis. (2) Methods: We analyzed data from 936 TEE examinations performed at a high volume center in patients referred for TLE from 2015 to 2019. The follow-up was 566.2 ± 224.5 days. (3)  ...[more]

Similar Datasets

| S-EPMC8207345 | biostudies-literature
| S-EPMC6354182 | biostudies-other
| S-EPMC8764071 | biostudies-literature
| S-EPMC4691200 | biostudies-literature
| S-EPMC6742405 | biostudies-literature
| S-EPMC8485817 | biostudies-literature
| S-EPMC7887444 | biostudies-literature
| S-EPMC7987895 | biostudies-literature
| S-EPMC8745716 | biostudies-literature
| S-EPMC6488060 | biostudies-literature