Unknown

Dataset Information

0

Feasibility and reference intervals assessed by conventional and speckle-tracking echocardiography in normal hamsters.


ABSTRACT:

Objectives

This study aimed to determine feasibility, reference intervals, and reproducibility of left ventricular ejection fraction (LVEF) and speckle-tracking echocardiography (STE) in adult Syrian hamsters.

Background

Syrian hamster is an experimental model for several heart diseases. Echocardiography allows the evaluation of structure and function with bidimensional conventional techniques and STE. However, there is no data regarding reference values for bidimensional LVEF and myocardial strain in hamsters.

Methods

A total of 135 female Syrian hamsters were anesthetized and studied with a small animal dedicated echocardiography system. Echocardiography measurements were obtained from M-mode and B-mode images. Feasibility and 95% reference intervals were obtained for LVEF using three different approaches: LVEF_Teichholz (from M-mode linear measurements), LVEF_BMode (from area-length method), and LVEF_ STE (from strain), and for global longitudinal (GLS), circumferential (GCS), and radial (GRS) endocardial strain. Reproducibility was assessed as intra-class correlation coefficients.

Results

Feasibility of LVEF and endocardial strain was high (95% in FEVE_Teichholz, 93% in the LVEF_BMode, 84% in the LVEF_STE, 84% from PSLAX, and 80% from PSSAX). Values of LVEF_Teichholz were significantly higher than values of LVEF_BMode, and LVEF_STE-derived methods (59.0 ± 5.8, 53.8 ± 4.7, 46.3 ± 5.7, p < 0.0001). The 95% reference intervals for GLS, GCS, and GRS were respectively -13.6(-7.5;-20.4)%, -20.5 ± 3.1%, and + 34,7 ± 7.0%. Intra-class correlation coefficients were 0.49 - 0.91 for LVEF measurements, 0.73 - 0.92 for STE, with better results for LVEF_Teichholz and GLS.

Conclusions

Evaluation of LVEF by several methods and STE parameters is feasible in hamsters. Reference intervals for LVEF and STE obtained for this experimental animal model can be applied at future research.

SUBMITTER: Barros Filho ACL 

PROVIDER: S-EPMC7923569 | biostudies-literature | 2021 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Feasibility and reference intervals assessed by conventional and speckle-tracking echocardiography in normal hamsters.

Barros Filho Antonio C L ACL   Moreira Henrique T HT   Dias Beatriz P BP   Ribeiro Fernando F F FFF   Tanaka Denise M DM   Schmidt André A   Maciel Benedito C BC   Simões Marcus V MV   Marin-Neto José A JA   Romano Minna M D MMD  

Physiological reports 20210301 5


<h4>Objectives</h4>This study aimed to determine feasibility, reference intervals, and reproducibility of left ventricular ejection fraction (LVEF) and speckle-tracking echocardiography (STE) in adult Syrian hamsters.<h4>Background</h4>Syrian hamster is an experimental model for several heart diseases. Echocardiography allows the evaluation of structure and function with bidimensional conventional techniques and STE. However, there is no data regarding reference values for bidimensional LVEF and  ...[more]

Similar Datasets

| S-EPMC5822665 | biostudies-literature
| S-EPMC7168914 | biostudies-literature
| S-EPMC5491258 | biostudies-literature
| S-EPMC7793052 | biostudies-literature
| S-EPMC9289460 | biostudies-literature
| S-EPMC7969695 | biostudies-literature
| S-EPMC6700482 | biostudies-literature
| S-EPMC3800696 | biostudies-literature
| S-EPMC8302535 | biostudies-literature
| S-EPMC7838225 | biostudies-literature