Unknown

Dataset Information

0

Amyloid burden quantification depends on PET and MR image processing methodology.


ABSTRACT: Quantification of amyloid load with positron emission tomography can be useful to assess Alzheimer's Disease in-vivo. However, quantification can be affected by the image processing methodology applied. This study's goal was to address how amyloid quantification is influenced by different semi-automatic image processing pipelines. Images were analysed in their Native Space and Standard Space; non-rigid spatial transformation methods based on maximum a posteriori approaches and tissue probability maps (TPM) for regularisation were explored. Furthermore, grey matter tissue segmentations were defined before and after spatial normalisation, and also using a population-based template. Five quantification metrics were analysed: two intensity-based, two volumetric-based, and one multi-parametric feature. Intensity-related metrics were not substantially affected by spatial normalisation and did not significantly depend on the grey matter segmentation method, with an impact similar to that expected from test-retest studies (?10%). Yet, volumetric and multi-parametric features were sensitive to the image processing methodology, with an overall variability up to 45%. Therefore, the analysis should be carried out in Native Space avoiding non-rigid spatial transformations. For analyses in Standard Space, spatial normalisation regularised by TPM is preferred. Volumetric-based measurements should be done in Native Space, while intensity-based metrics are more robust against differences in image processing pipelines.

SUBMITTER: Kolinger GD 

PROVIDER: S-EPMC7935288 | biostudies-literature | 2021

REPOSITORIES: biostudies-literature

altmetric image

Publications


Quantification of amyloid load with positron emission tomography can be useful to assess Alzheimer's Disease in-vivo. However, quantification can be affected by the image processing methodology applied. This study's goal was to address how amyloid quantification is influenced by different semi-automatic image processing pipelines. Images were analysed in their Native Space and Standard Space; non-rigid spatial transformation methods based on maximum a posteriori approaches and tissue probability  ...[more]

Similar Datasets

| S-EPMC6910644 | biostudies-literature
| S-EPMC6899618 | biostudies-literature
| S-EPMC8204268 | biostudies-literature
| S-EPMC3117895 | biostudies-other
| S-EPMC6207312 | biostudies-literature
| S-EPMC3477199 | biostudies-other
| S-EPMC6602134 | biostudies-literature
| S-EPMC6710378 | biostudies-literature
| S-EPMC7596768 | biostudies-literature
| S-EPMC9140104 | biostudies-literature