RetiSurge - Enabling "Dry Lab" vitreoretinal surgical training during COVID-19 pandemic.
Ontology highlight
ABSTRACT: The COVID-19 pandemic has resulted in reduction of patient volumes in Ophthalmology. With only emergency surgical procedures being performed with few elective surgical procedures, surgical volumes are at an all-time low. This has resulted in decreased surgical training opportunities for trainee surgeons. We developed a simple, cost-effective, 3D printed model eye - RetiSurge - for "Dry Lab" vitreoretinal surgery training. The model incorporates a retinal film that can be changed, making it suitable for multiple uses. The RetiSurge model can be used to practice visualization, instrument manipulation and endolaser photocoagulation. RetiSurge can be sterilized by ethylene oxide and is safe for use inside the operating room. RetiSurge is a simple, cost-effective, and reusable model eye for early training in Vitreoretinal surgery.
SUBMITTER: Chhabra K
PROVIDER: S-EPMC8012966 | biostudies-literature |
REPOSITORIES: biostudies-literature
ACCESS DATA