Unknown

Dataset Information

0

Surgical Explantation of a Fenestrated Endovascular Abdominal Aortic Aneurysm Repair Device Complicated by Aorto-Enteric Fistula.


ABSTRACT:

Introduction

Alarming outcomes have been reported following infected endovascular aortic aneurysm repair (EVAR) device explantation. Infected fenestrated EVAR (FEVAR) exposes patients to even worse procedural risks.

Report

A 67 year old man with a prior history of FEVAR presented with impaired general condition, abdominal and back pain, and increased C reactive protein. Computed tomography angiography revealed a collection around the aortic graft bifurcation and 18F-fluorodeoxyglucose-positron emission tomography (FDG-PET) revealed increased FDG uptake at this level, confirmed by labelled white blood cells, all favouring graft infection. A thoracophrenolumbotomy was performed and revealed an aorto-enteric fistula which was treated by small bowel resection. The left renal artery was transected at the distal end of the bridging stent and a thoracorenal bypass was performed. The thoracic aorta was cross clamped above the coeliac trunk for complete graft excision. Meanwhile, the right kidney was perfused with 4°C Ringer lactate solution. In situ reconstruction was accomplished with a bifurcated antimicrobial graft sutured below the superior mesenteric artery with re-implantation of the right renal artery. The patient was left with a laparostomy for definitive abdominal closure, restoration of the digestive tract, and omental wrap 72 hours later. Broad spectrum antibiotic therapy was initiated peri-operatively and reduced to sulfamethoxazole/trimethoprim for a total duration of six weeks after one sample was positive for Moraxella osloensis. Eleven months later, the patient was free from re-infection, with no fever or inflammatory syndrome.

Discussion

Total explantation of stent grafts with tissue debridement and post-operative antibiotic therapy is the gold standard when dealing with infected EVAR. As with type IV thoraco-abdominal aneurysm open repair, FEVAR device explantation requires additional protective measures to prevent visceral ischaemia and renal impairment. In agreement with the European Society for Vascular Surgery guidelines, such patients should be referred to dedicated vascular centres with expertise in surgical repair, anaesthetics, and post-operative intensive care.

SUBMITTER: Caradu C 

PROVIDER: S-EPMC8077032 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC7873572 | biostudies-literature
| S-EPMC5902886 | biostudies-literature
| S-EPMC8288752 | biostudies-literature
| S-EPMC5485015 | biostudies-literature
| S-EPMC7378364 | biostudies-literature
| S-EPMC6773647 | biostudies-literature
| S-EPMC7991710 | biostudies-literature
| S-EPMC8077236 | biostudies-literature
| S-EPMC5559182 | biostudies-literature
| S-EPMC5548202 | biostudies-other