Project description:Rapid onsite whole-genome sequencing of two suspected severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) N gene diagnostic escape samples revealed a previously unreported N gene point mutation at genome position 29195. Because the G29195T mutation occurs within a region probed by a commonly referenced U.S. CDC N gene reverse transcription (RT)-PCR assay, we hypothesize that the G29195T mutation rendered the N gene target of a proprietary commercial assay undetectable. The putative diagnostic escape G29195T mutation demonstrates the need for nearly real-time surveillance, as emergence of a novel SARS-CoV-2 variant with the potential to escape diagnostic tests continues to be a threat. IMPORTANCE Accurate diagnostic detection of SARS-CoV-2 currently depends on the large-scale deployment of RT-PCR assays. SARS-CoV-2 RT-PCR assays target predetermined regions in the viral genomes by complementary binding of primers and probes to nucleic acid sequences in the clinical samples. Potential diagnostic escapes, such as those of clinical samples harboring the G29195T mutation, may result in false-negative SARS-CoV-2 RT-PCR results. The rapid detection and sharing of potential diagnostic escapes are essential for diagnostic laboratories and manufacturers around the world, to optimize their assays as SARS-CoV-2 continues to evolve.
Project description:We developed an assay that detects minus-strand RNA as a surrogate for actively replicating severe acute respiratory syndrome coronavirus 2. We detected minus-strand RNA in 41 persons with coronavirus disease up to 30 days after symptom onset. This assay might inform clinical decision-making about patient infectiousness.
Project description:Most individuals acutely infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) exhibit mild symptoms. However, 10 to 20% of those infected develop long-term symptoms, referred to as post-coronavirus disease 2019 (COVID-19) condition (PCC). One hypothesis is that PCC might be exacerbated by viral persistence in tissue sanctuaries. Therefore, the accurate detection and quantification of SARS-CoV-2 are not only necessary for viral load monitoring but also crucial for detecting long-term viral persistence and determining whether viral replication is occurring in tissue reservoirs. In this study, the sensitivity and robustness of reverse transcription (RT)-droplet digital PCR (ddPCR) and RT-quantitative PCR (qPCR) techniques have been compared for the detection and quantification of SARS-CoV-2 genomic and subgenomic RNAs from oropharyngeal swabs taken from confirmed SARS-CoV-2-positive, SARS-CoV-2-exposed, and nonexposed individuals as well as from samples from mice infected with SARS-CoV-2. Our data demonstrated that both techniques presented equivalent results in the mid- and high-viral-load ranges. Additionally, RT-ddPCR was more sensitive than RT-qPCR in the low-viral-load range, allowing the accurate detection of positive results in individuals exposed to the virus. Overall, these data suggest that RT-ddPCR might be an alternative to RT-qPCR for detecting low viral loads in samples and for assessing viral persistence in samples from individuals with PCC. IMPORTANCE We developed one-step reverse transcription (RT)-droplet digital PCR (ddPCR) protocols to detect SARS-CoV-2 RNA and compared them to the gold-standard RT-quantitative PCR (RT-qPCR) method. RT-ddPCR was more sensitive than RT-qPCR in the low-viral-load range, while both techniques were equivalent in the mid- and high-viral-load ranges. Overall, these results suggest that RT-ddPCR might be a viable alternative to RT-qPCR when it comes to detecting low viral loads in samples, which is a highly relevant issue for determining viral persistence in as-yet-unknown tissue reservoirs in individuals suffering from post-COVID conditions or long COVID.
Project description:Piscine orthoreovirus (PRV) infects farmed and wild salmon and trout species in North America, South America, Europe, and East Asia. PRV groups into three distinct genotypes (PRV-1, PRV-2, and PRV-3) that can vary in distribution, host specificity, and/or disease potential. Detection of the virus is currently restricted to genotype specific assays such that surveillance programs require the use of three assays to ensure universal detection of PRV. Consequently, herein, we developed, optimized, and validated a real-time reverse transcription quantitative PCR assay (RT-qPCR) that can detect all known PRV genotypes with high sensitivity and specificity. Targeting a conserved region at the 5' terminus of the M2 segment, the pan-PRV assay reliably detected all PRV genotypes with as few as five copies of RNA. The assay exclusively amplifies PRV and does not cross-react with other salmonid viruses or salmonid host genomes and can be performed as either a one- or two-step RT-qPCR. The assay is highly reproducible and robust, showing 100% agreement in test results from an inter-laboratory comparison between two laboratories in two countries. Overall, as the assay provides a single test to achieve highly sensitive pan-specific PRV detection, it is suitable for research, diagnostic, and surveillance purposes.
Project description:The emergence of a new coronavirus in Wuhan China has triggered a global need for accurate diagnostic assays. Initially, mostly laboratory developed molecular tests were available but shortly thereafter different commercial assays started to appear and are still increasing in number. Although independent performance evaluations are ongoing, available data is still scarce. Here we provide a direct comparison of key performance characteristics of 13 commercial RT-PCR assays. Thirteen RT-PCR assays were selected based on the criteria that they can be used following generic RNA extraction protocols, on common PCR platforms and availability. Using a 10-fold and 2-fold dilution series of a quantified SARS-CoV-2 cell-cultured virus stock, performance was assessed compared to our in house validated assay. Specificity was tested by using RNA extracted from cultured common human coronaviruses. All RT-PCR kits included in this study exhibited PCR efficiencies > 90%, except for the Sentinel Diagnostics B E-gene RUO assay (80%). Analytical sensitivity varied between 3.3 RNA copies to 330 RNA copies. Only one assay cross reacted with another human coronavirus (MERS). This study provides a technical baseline of 13 different commercial PCR assays for SARS-CoV-2 detection that can be used by laboratories interested in purchasing any of these for further full clinical validation.
Project description:BackgroundCycle threshold (Ct) values from SARS-CoV-2 reverse transcription quantitative PCR (RT-qPCR) tests are used to measure viral burden. Calibration to the First WHO International Standard for SARS-CoV-2 RNA may improve quantitative inter-assay agreement.MethodsWHO standard was tested using four emergency use authorized RT-qPCRs to generate calibration curves and evaluate Ct value differences. Harmonization of two assays, Cepheid Xpert Xpress SARS-CoV-2 targeting E and nucleocapsid (N2) [Xpert (E) and Xpert (N2)] and a laboratory-developed test targeting E [LDT (E)], was assessed using 93 positive upper respiratory samples. Platform (target) pairs were compared via Bland-Altman analysis and Passing-Bablok regression.ResultsCt values with the WHO standard were comparable across platforms and targets, except Xpert (N2) for which the mean difference was a median of 3.68 cycles (Interquartile Range, IQR = 3.23 to 3.76 cycles) greater than other platform (target) pairs. Using clinical samples, the mean difference of Xpert (N2) to LDT (E) was 3.64 cycles (95% Confidence Interval, CI =1.51 to 5.76). After calibration, the mean difference of Xpert (N2) to LDT (E) was 0.08 log10 IU/mL (95% CI = -0.56 to 0.71) and the regression was y = 1.00x * 0.08 (95% CI slope = 0.93 to 1.07, 95% CI intercept = 0.28 to 0.42).ConclusionsCalibration to the WHO standard resulted in the harmonization of two RT-qPCR tests, whereas analysis by Ct value alone may have led to erroneous quantitation. Harmonization to the WHO standard has the potential to improve the generalizability of clinical associations with SARS-CoV-2 RNA levels.
Project description:With the emergence and wide spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs), such as the Delta variant (B.1.617.2 lineage and AY sublineage), it is important to track VOCs for sourcing of transmission. Currently, whole-genome sequencing is commonly used for detecting VOCs, but this is limited by the high costs of reagents and sophisticated sequencers. In this study, common mutations in the genomes of SARS-CoV-2 VOCs were identified by analyzing more than 1 million SARS-CoV-2 genomes from public data. Among them, mutations C1709A (a change of C to A at position 1709) and C56G, respectively, were found in more than 99% of the genomes of Alpha and Delta variants and were specific to them. Then, a method using the amplification refractory mutation system combined with quantitative reverse transcription-PCR (ARMS-RT-qPCR) based on the two mutations was developed for identifying both VOCs. The assay can detect as little as 1 copy/μL of the VOCs, and the results for identifying Alpha and Delta variants in clinical samples by the ARMS-RT-qPCR assay showed 100% agreement with the results using sequencing-based methods. The whole assay can be completed in 2.5 h using commercial fluorescent PCR instruments. Therefore, the ARMS-RT-qPCR assay could be used for screening the two highly concerning variants Alpha and Delta by normal PCR laboratories in airports and in hospitals and other health-related organizations. Additionally, based on the unique mutations identified by the genomic analysis, similar molecular assays can be developed for rapid identification of other VOCs. IMPORTANCE The current stage of the pandemic, led by SARS-CoV-2 variants of concern (VOCs), underscores the necessity to develop a cost-effective and rapid molecular diagnosis assay to differentiate the VOCs. In this study, over 1 million SARS-CoV-2 genomic sequences of high quality from GISAID were analyzed and a network of the common mutations of the lineages was constructed. The conserved unique mutations specific for SARS-CoV-2 VOCs were found. Then, ARMS-RT-qPCR assays based on the two unique mutations of the Alpha and Delta variants were developed for the detection of the two VOCs. Application of the assay in clinical samples demonstrated that the current method is a convenient, cost-effective, and rapid way to screen the target SARS-CoV-2 VOCs.
Project description:BackgroundSince its beginning, the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has been a challenge for clinical and molecular diagnostics, because it has been caused by a novel viral agent. Whole-genome sequencing assisted in the characterization and classification of SARS-CoV-2, and it is an essential tool to genomic surveillance aiming to identify potentials hot spots that could impact on vaccine immune response and on virus diagnosis. We describe two cases of failure at the N2 target of the RT-PCR test Xpert® Xpress SARS-CoV-2.MethodsTotal nucleic acid from the Nasopharyngeal (NP) and oropharyngeal (OP) swab samples and cell supernatant isolates were obtained. RNA samples were submitted to random amplification. Raw sequencing data were subjected to sequence quality controls, removal of human contaminants by aligning against the HG19 reference genome, taxonomic identification of other pathogens and genome recovery through assembly and manual curation. RT-PCR test Xpert® Xpress SARS-CoV-2 was used for molecular diagnosis of SARS-CoV-2 infection, samples were tested in duplicates.ResultsWe identified 27 samples positive for SARS-CoV-2 with a nucleocapsid (N) gene drop out on Cepheid Xpert® Xpress SARS-CoV-2 assay. Sequencing of 2 of 27 samples revealed a single common mutation in the N gene C29197T, potentially involved in the failed detection of N target.ConclusionsThis study highlights the importance of genomic data to update molecular tests and vaccines.
Project description:Sensitive and reliable diagnostic test systems based on real-time PCR are of great importance in the fight against the ongoing SARS-CoV-2 pandemic. The genetic variability of the SARS-CoV-2 virus leads to the accumulation of mutations, some of which may affect the sensitivity of modern PCR assays. The aim of this study was to search in Russian clinical samples for new mutations in SARS-CoV-2 gene N that can affect the detection by RT-PCR. In this study, the polymorphisms in the regions of the target gene N causing failed or poor detection of the target N in the RT-PCR assay on 12 selected samples were detected. Sequencing the entire N and E genes in these samples along with other 195 samples that were positive for both target regions was performed. Here, we identified a number of nonsynonymous mutations and one novel deletion in the N gene that affected the ability to detect a target in the N gene as well a few mutations in the E gene of SARS-CoV-2 that did not affect detection. Sequencing revealed that majority of the mutations in the N gene were located in the variable region between positions 193 and 235 aa, inside and nearby the phosphorylated serine-rich region of the protein N. This study highlights the importance of the further characterization of the genetic variability and evolution of gene N, the most common target for detecting SARS-CoV-2. The use of at least two targets for detecting SARS-CoV-2, including one for the E gene, will be necessary for reliable diagnostics.