Aortic Annular Sizing Using Novel Software in Three-Dimensional Transesophageal Echocardiography for Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.


ABSTRACT: (1) Background: We performed this study to evaluate the agreement between novel automated software of three-dimensional transesophageal echocardiography (3D-TEE) and multidetector computed tomography (MDCT) for aortic annular measurements of preprocedural transcatheter aortic valve replacement (TAVR); (2) Methods: PubMed, EMBASE, Web of Science, and Cochrane Library (Wiley) databases were systematically searched for studies that compared 3D-TEE and MDCT as the reference standard for aortic annular measurement of the following parameters: annular area, annular perimeter, area derived-diameter, perimeter derived-diameter, maximum and minimum diameter. Meta-analytic methods were utilized to determine the pooled correlations and mean differences between 3D-TEE and MDCT. Heterogeneity and publication bias were also assessed. Meta-regression analyses were performed based on the potential factors affecting the correlation of aortic annular area; (3) Results: A total of 889 patients from 10 studies were included in the meta-analysis. Pooled correlation coefficients between 3D-TEE and MDCT of annulus area, perimeter, area derived-diameter, perimeter derived-diameter, maximum and minimum diameter measurements were strong 0.89 (95% CI: 0.84-0.92), 0.88 (95% CI: 0.83-0.92), 0.87 (95% CI: 0.77-0.93), 0.87 (95% CI: 0.77-0.93), 0.79 (95% CI: 0.64-0.87), and 0.75 (95% CI: 0.61-0.84) (Overall p < 0.0001), respectively. Pooled mean differences between 3D-TEE and MDCT of annulus area, perimeter, area derived-diameter, perimeter derived-diameter, maximum and minimum diameter measurements were -20.01 mm2 ((95% CI: -35.37 to -0.64), p = 0.011), -2.31 mm ((95% CI: -3.31 to -1.31), p < 0.0001), -0.22 mm ((95% CI: -0.73 to 0.29), p = 0.40), -0.47 mm ((95% CI: -1.06 to 0.12), p = 0.12), -1.36 mm ((95% CI: -2.43 to -0.30), p = 0.012), and 0.31 mm ((95% CI: -0.15 to 0.77), p = 0.18), respectively. There were no statistically significant associations with the baseline patient characteristics of sex, age, left ventricular ejection fraction, mean transaortic gradient, and aortic valve area to the correlation between 3D-TEE and MDCT for aortic annular area sizing; (4) Conclusions: The present study implies that 3D-TEE using novel software tools, automatically analysis, is feasible to MDCT for annulus sizing in clinical practice.

SUBMITTER: Mork C 

PROVIDER: S-EPMC8145366 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC4854149 | biostudies-other
| S-EPMC8237423 | biostudies-literature
| S-EPMC6806040 | biostudies-literature
| S-EPMC6727651 | biostudies-literature
| S-EPMC7702059 | biostudies-literature
| S-EPMC6058250 | biostudies-literature
| S-EPMC8649494 | biostudies-literature
| S-EPMC5815465 | biostudies-literature
| S-EPMC8299247 | biostudies-literature