Potency Assessment of Dendritic Cell Anticancer Vaccine: Validation of the Co-Flow DC Assay.
Ontology highlight
ABSTRACT: For many years, oncological clinical trials have taken advantage of dendritic cells (DC) for the design of DC-based cellular therapies. This has required the design of suitable quality control assays to evaluate the potency of these products. The purpose of our work was to develop and validate a novel bioassay that uses flow cytometry as a read-out measurement. In this method, CD3+ cells are labeled with a fluorescent dye and the DC costimulatory activity is measured by the degree of T cell proliferation caused by the DC-T cell interaction. The validation of the method was achieved by the evaluation of essential analytical parameters defined by international guidelines. Our results demonstrated that the method could be considered specific, selective, and robust. The comparison between measured values and estimated true values confirmed a high level of accuracy and a lack of systematic error. Repeated experiments have shown the reproducibility of the assay and the proportionality between the potency and the DC amount has proven its linearity. Our results suggest that the method is compliant with the guidelines and could be adopted as a quality control assay or batch-release testing within GMP facilities.
SUBMITTER: Carloni S
PROVIDER: S-EPMC8198694 | biostudies-literature |
REPOSITORIES: biostudies-literature
ACCESS DATA