Clinical effectiveness of a dedicated cardiac resynchronization therapy pre-assessment clinic incorporating cardiac magnetic resonance imaging and cardiopulmonary exercise testing on patient selection and outcomes.


ABSTRACT:

Background

Pre-procedural assessment of patients undergoing cardiac resynchronization therapy (CRT) is heterogenous and patients implanted with unfavorable characteristics may account for non-response. A dedicated CRT pre-assessment clinic (CRT PAC) was developed to standardize the review process and undertake structured pre-procedural evaluation. The aim of this analysis was to determine the effectiveness on patient selection and outcomes.

Methods

A prospective database of consecutive patients attending the CRT PAC between 2013 and 2018 was analyzed. Pre-operative assessment included cardiac magnetic resonance (CMR) and cardiopulmonary exercise testing (CPET). Patients were considered CRT responders based on improvement in clinical composite score (CCS) and/or reduction in left ventricular end-systolic volume (LVESV) ≥ 15% at 6-months follow-up.

Results

Of 252 patients reviewed in the CRT PAC during the analysis period, 192 fulfilled consensus guidelines for implantation. Of the patients receiving CRT, 82% showed improvement in their CCS and 57% had a reduction in LVESV ≥ 15%. The presence of subendocardial scar on CMR and a peak VO2 ≤ 12 ml/kg/min on CPET predicted CRT non-response. Two patients were unsuitable for CRT as they had end-stage heart failure and died during follow-up. The majority of patients initially deemed unsuitable for CRT did not suffer from unexpected hospitalization for decompensated heart failure or died from cardiovascular disease; only 8 patients (13%) received CRT devices during follow-up because of symptomatic left ventricular systolic impairment.

Conclusion

A dedicated CRT PAC is able to appropriately select patients for CRT. Pre-procedural investigation/imaging can identify patients unlikely to respond to, or may not yet be suitable for CRT.

SUBMITTER: Sidhu BS 

PROVIDER: S-EPMC8203725 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC2000933 | biostudies-literature
| S-EPMC2994940 | biostudies-literature
| S-EPMC7487601 | biostudies-literature
| S-EPMC8754079 | biostudies-literature
| S-EPMC7125548 | biostudies-literature
| S-EPMC4315486 | biostudies-other
| S-EPMC7549205 | biostudies-literature
| S-EPMC3964325 | biostudies-literature
| S-EPMC6023574 | biostudies-literature
| S-EPMC6752801 | biostudies-literature