Unknown

Dataset Information

0

A prototype device of microliter volume voltammetric pH sensor based on carbazole-quinone redox-probe tethered MWCNT modified three-in-one screen-printed electrode.


ABSTRACT: As an alternate for the conventional glass-based pH sensor which is associated with problems like fragile nature, alkaline error, and potential drift, the development of a new redox-sensitive pH probe-modified electrode that could show potential, current-drift and surface-fouling free voltammetric pH sensing is a demanding research interest, recently. Herein, we report a substituted carbazole-quinone (Car-HQ) based new redox-active pH-sensitive probe that contains benzyl and bromo-substituents, immobilized multiwalled carbon nanotube modified glassy carbon (GCE/MWCNT@Car-HQ) and screen-printed three-in-one (SPE/MWCNT@Car-HQ) electrodes for selective, surface-fouling free pH sensor application. This new system showed a well-defined surface-confined redox peak at an apparent standard electrode potential, Eo' = - 0.160 V versus Ag/AgCl with surface-excess value, Γ = 47 n mol cm-2 in pH 7 phosphate buffer solution. When tested with various electroactive chemicals and biochemicals such as cysteine, hydrazine, NADH, uric acid, and ascorbic acid, MWCNT@Car-HQ showed an unaltered redox-peak potential and current values without mediated oxidation/reduction behavior unlike the conventional hydroquinone, anthraquinone and other redox mediators based voltammetry sensors with serious electrocatalytic effects and in turn potential and current drifts. A strong π-π interaction, nitrogen-atom assisted surface orientation and C-C bond formation on the graphitic structure of MWCNT are the plausible reasons for stable and selective voltammetric pH sensing application of MWCNT@Car-HQ system. Using a programed/in-built three-in-one screen printed compatible potentiostat system, voltammetric pH sensing of 3 μL sample of urine, saliva, and orange juice samples with pH values comparable to that of milliliter volume-based pH-glass electrode measurements has been demonstrated.

SUBMITTER: Srinivas S 

PROVIDER: S-EPMC8260652 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC10826182 | biostudies-literature
| S-EPMC7472020 | biostudies-literature
| S-EPMC10609049 | biostudies-literature
| S-EPMC6864816 | biostudies-literature
| S-EPMC9234029 | biostudies-literature
| S-EPMC9933535 | biostudies-literature
| S-EPMC5452743 | biostudies-other
| S-EPMC1144104 | biostudies-other
| S-EPMC8153944 | biostudies-literature
| S-EPMC8125155 | biostudies-literature