Project description:To evaluate the immunogenicity of inactivated COVID-19 vaccines administered at different intervals. Subjects who had received two doses of inactivated COVID-19 vaccines at an interval of 21 days or 1-7 months were selected to collect 5 ml of venous blood after the second dose for the detection of specific IgG antibody against SARS-CoV-2 using the chemiluminescent immunoassay. Blood samples were collected from 348 and 174 individuals vaccinated at an interval of 21 days or 1-7 months, respectively. Seropositive rate 2 weeks after two doses of vaccination at 21-days and 1-7 months interval was 95.7% and 97.1%, respectively, with no statistically significant difference. The post-vaccination antibody level was 23.7 with 21-days interval, higher than 14.2 with 1-7 months interval. Among the individuals vaccinated with two doses more than 1-month apart, seropositive rate was 98.5%, 90.0%, 91.7%, and 100% with 1- month (1-2 months, 2 months was not included, the same below), 2- month, 3- month, and 4-7 months of interval, respectively, and no statistically significant difference was observed. Appropriate extension of the vaccination interval between two doses of inactivated COVID-19 vaccine does not affect the production of specific IgG antibodies. The inactivated COVID-19 vaccine should be administered in accordance with the recommended vaccination schedule, and the vaccination interval can be extended appropriately under special circumstances.
Project description:BackgroundUnderstanding immunogenicity and effectiveness of SARS-CoV-2 vaccines is critical to guide rational use.MethodsWe compared the immunogenicity of mRNA-1273, BNT-162b2 or Ad26.COV2.S in healthy ambulatory adults in Massachusetts, USA. To correlate immunogenicity with effectiveness of the three vaccines, we performed an inverse-variance meta-analysis of population level effectiveness from public health reports in >40 million individuals.ResultsA single dose of either mRNA vaccine yielded comparable antibody and neutralization titers to convalescent individuals. Ad26.COV2.S yielded lower antibody concentrations and frequently undetectable neutralization titers. Bulk and cytotoxic T-cell responses were higher in mRNA1273 and BNT162b2 than Ad26.COV2.S recipients. Regardless of vaccine, <50% of vaccinees demonstrated CD8+ T-cell responses. Antibody concentrations and neutralization titers increased comparably after the first dose of either vaccine, and further in recipients of a second dose. Prior infection was associated with high antibody concentrations and neutralization even after a single dose and regardless of vaccine. Neutralization of beta, gamma and delta strains were poorer regardless of vaccine. In meta-analysis, relative to mRNA1273 the effectiveness of BNT162b2 was lower against infection and hospitalization; and Ad26COV2.S was lower against infection, hospitalization and death.ConclusionsVariation in the immunogenicity correlates with variable effectiveness of the three FDA EUA vaccines deployed in the USA.
Project description:The emergence of SARS-CoV-2 variants may impact the effectiveness of vaccines, while heterologous vaccine strategy is considered to provide better protection. The immunogenicity of an mRNA-inactivated virus vaccine against the SARS-CoV-2 wild-type (WT) and variants was evaluated in the study. SARS-CoV-2 naïve adults (n = 123) were recruited and placed in the following groups: BNT162b2, CoronaVac or BNT162b2-CoronaVac (Combo) Group. Blood samples were collected to measure neutralization antibodies (NAb) by a live virus microneutralization assay (vMN) and surrogate NAb test. The day 56 vMN geometric mean titre (GMT) was 26.2 [95% confident interval (CI), [22.3-30.9] for Combo, 136.9 (95% CI, 104.2-179.7) for BNT162b2, and 14.7 (95% CI, 11.6-18.6) for CoronaVac groups. At 6 months post-first dose, the GMT declined to 8.0, 28.8 and 7.1 in the Combo, BNT162b2 and CoronaVac groups, respectively. Three groups showed reduced neutralizing activity against D614G, beta, theta and delta variants. At day 56 GMT (74.6) and month 6 GMT (22.7), the delta variant in the BNT162b2 group was higher than that in the Combo (day 56, 7.4; month 6, 5.5) and CoronaVac groups (day 56, 8.0; month 6, 5) (p < 0.0001). Furthermore, the mean surrogate NAb value on day 56 in the BNT162b2 group was 594.7 AU/mL and higher than 40.5 AU/mL in Combo and 38.8 AU/mL in CoronaVac groups (p < 0.0001). None of the participants developed severe adverse events, and all other adverse events were self-limiting. The Combo vaccination strategy was safe. The overall vaccine immunogenicity at day 56 and 6 months were comparable to the homologous CoronaVac group but inferior to the homologous BNT162b2 group, against both the WT and all variants. Furthermore, the antibody response of vaccines waned at 6 months and thereby, a third dose of the vaccine is needed for these vaccines.
Project description:The coronavirus disease 2019 (COVID-19) pandemic has become a severe healthcare problem worldwide since the first outbreak in late December 2019. Currently, the COVID-19 vaccine has been used in many countries, but it is still unable to control the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, despite patients receiving full vaccination doses. Therefore, we aimed to appraise the booster effect of the different platforms of vaccines, including inactivated vaccine (BBIBP), viral vector vaccine (AZD122), and mRNA vaccine (BNT162b2), in healthy adults who received the full dose of inactivated vaccine (CoronaVac). The booster dose was safe with no serious adverse events. Moreover, the immunogenicity indicated that the booster dose with viral vector and mRNA vaccine achieved a significant proportion of Ig anti-receptor binding domain (RBD), IgG anti-RBD, and IgA anti-S1 booster response. In contrast, inactivated vaccine achieved a lower booster response than others. Consequently, the neutralization activity of vaccinated serum had a high inhibition of over 90% against SARS-CoV-2 wild-type and their variants (B.1.1.7-alpha, B.1.351-beta, and B.1.617.2-delta). In addition, IgG anti-nucleocapsid was observed only among the group that received the BBIBP booster. Our study found a significant increase in levels of IFN-ɣ secreting T-cell response after the additional viral vector or mRNA booster vaccination. This study showed that administration with either viral vector (AZD1222) or mRNA (BNT162b2) boosters in individuals with a history of two doses of inactivated vaccine (CoronaVac) obtained great immunogenicity with acceptable adverse events.
Project description:ImportancePregnant women are at increased risk of morbidity and mortality from COVID-19 but have been excluded from the phase 3 COVID-19 vaccine trials. Data on vaccine safety and immunogenicity in these populations are therefore limited.ObjectiveTo evaluate the immunogenicity of COVID-19 messenger RNA (mRNA) vaccines in pregnant and lactating women, including against emerging SARS-CoV-2 variants of concern.Design, setting, and participantsAn exploratory, descriptive, prospective cohort study enrolled 103 women who received a COVID-19 vaccine from December 2020 through March 2021 and 28 women who had confirmed SARS-CoV-2 infection from April 2020 through March 2021 (the last follow-up date was March 26, 2021). This study enrolled 30 pregnant, 16 lactating, and 57 neither pregnant nor lactating women who received either the mRNA-1273 (Moderna) or BNT162b2 (Pfizer-BioNTech) COVID-19 vaccines and 22 pregnant and 6 nonpregnant unvaccinated women with SARS-CoV-2 infection.Main outcomes and measuresSARS-CoV-2 receptor binding domain binding, neutralizing, and functional nonneutralizing antibody responses from pregnant, lactating, and nonpregnant women were assessed following vaccination. Spike-specific T-cell responses were evaluated using IFN-γ enzyme-linked immunospot and multiparameter intracellular cytokine-staining assays. Humoral and cellular immune responses were determined against the original SARS-CoV-2 USA-WA1/2020 strain as well as against the B.1.1.7 and B.1.351 variants.ResultsThis study enrolled 103 women aged 18 to 45 years (66% non-Hispanic White) who received a COVID-19 mRNA vaccine. After the second vaccine dose, fever was reported in 4 pregnant women (14%; SD, 6%), 7 lactating women (44%; SD, 12%), and 27 nonpregnant women (52%; SD, 7%). Binding, neutralizing, and functional nonneutralizing antibody responses as well as CD4 and CD8 T-cell responses were present in pregnant, lactating, and nonpregnant women following vaccination. Binding and neutralizing antibodies were also observed in infant cord blood and breast milk. Binding and neutralizing antibody titers against the SARS-CoV-2 B.1.1.7 and B.1.351 variants of concern were reduced, but T-cell responses were preserved against viral variants.Conclusion and relevanceIn this exploratory analysis of a convenience sample, receipt of a COVID-19 mRNA vaccine was immunogenic in pregnant women, and vaccine-elicited antibodies were transported to infant cord blood and breast milk. Pregnant and nonpregnant women who were vaccinated developed cross-reactive antibody responses and T-cell responses against SARS-CoV-2 variants of concern.
Project description:The ongoing COVID-19 pandemic and its unprecedented global societal and economic disruptive impact highlight the urgent need for safe and effective vaccines. Taking substantial advantages of versatility and rapid development, two mRNA vaccines against COVID-19 have completed late-stage clinical assessment at an unprecedented speed and reported positive results. In this review, we outline keynotes in mRNA vaccine development, discuss recently published data on COVID-19 mRNA vaccine candidates, focusing on those in clinical trials and analyze future potential challenges.
Project description:BackgroundEnterovirus 71 (EV71) is the major causative agent of hand, foot, and mouth disease (HFMD). Three inactivated EV71 whole-virus vaccines of different strains developed by different manufacturers in mainland China have recently entered clinical trials. Although several studies on these vaccines have been published, a study directly comparing the immunogenicity and protective effects among them has not been carried out, which makes evaluating their relative effectiveness difficult. Thus, properly comparing newly developed vaccines has become a priority, especially in China.Methods and findingsThis comparative immunogenicity study was carried out on vaccine strains (both live and inactivated), final container products (FCPs) without adjuvant, and corresponding FCPs containing adjuvant (FCP-As) produced by three manufacturers. These vaccines were evaluated by neutralizing antibody (NAb) responses induced by the same or different dosages at one or multiple time points post-immunization. The protective efficacy of the three vaccines was also determined in one-day-old ICR mice born to immunized female mice. Survival rates were observed in these suckling mice after challenge with 20 LD(50) of EV71/048M3C2. Three FCP-As, in a dose of 200 U, generated nearly 100% NAb positivity rates and similar geometric mean titers (GMTs), especially at 14-21 days post-inoculation. However, the dynamic NAb responses were different among three vaccine strains or three FCPs. The FCP-As at the lowest dose used in clinical trials (162 U) showed good protective effects in suckling mice against lethal challenge (90-100% survival), while the ED(50) of NAb responses and protective effects varied among three FCP-As.ConclusionsThese studies establish a standard method for measuring the immunogenicity of EV71 vaccines in mice. The data generated from our mouse model study indicated a clear dose-response relationship, which is important for vaccine quality control and assessment, especially for predicting protective efficacy in humans when combined with future clinical trial results.
Project description:In June 2021, Thailand was hit by the delta variant of SARS-CoV-2 resulting in the biggest wave of COVID-19. Due to the widespread delta variant, more than 600 healthcare workers had COVID-19 despite completion of two-dose CoronaVac. The Ministry of Public Health recommended that healthcare workers received a third dose of AZD1222 to increase level of protection against SARS-CoV-2. However, immune response after the AZD1222 booster in individuals who completed the two-dose CoronaVac vaccine are limited. In this study, sera from those who received a booster of AZD1222 in June-July 2021 were tested for SARS-CoV-2 spike receptor-binding-domain (RBD) IgG, anti-RBD total immunoglobulins and anti-spike protein 1 (S1) IgA. The neutralizing activities in a subset of serum samples were tested against the wild type and variants of concern (B.1.1.7, B.1.617.2, and B.1.351) using an enzyme-linked immunosorbent assay-based surrogate virus neutralization test. Participants who received the booster of AZD1222 possessed higher levels of spike RBD-specific IgG, total immunoglobulins, and anti-S1 IgA than the two-dose vaccinees (p < 0.001). They also elicited higher neutralizing activity against the wild type and all variants of concern than the recipients of the two-dose vaccines. This study demonstrated a high immunogenicity of the AZD1222 booster in individuals who completed the two-dose inactivated vaccines.
Project description:Two messenger RNA (mRNA) vaccines developed by Pfizer-BioNTech and Moderna are being rolled out. Despite the high volume of emerging evidence regarding adverse events (AEs) associated with the COVID-19 mRNA vaccines, previous studies have thus far been largely based on the comparison between vaccinated and unvaccinated control, possibly highlighting the AE risks with COVID-19 mRNA vaccination. Comparing the safety profile of mRNA vaccinated individuals with otherwise vaccinated individuals would enable a more relevant assessment for the safety of mRNA vaccination. We designed a comparative safety study between 18 755 and 27 895 individuals who reported to VigiBase for adverse events following immunization (AEFI) with mRNA COVID-19 and influenza vaccines, respectively, from January 1, 2020, to January 17, 2021. We employed disproportionality analysis to rapidly detect relevant safety signals and compared comparative risks of a diverse span of AEFIs for the vaccines. The safety profile of novel mRNA vaccines was divergent from that of influenza vaccines. The overall pattern suggested that systematic reactions like chill, myalgia, fatigue were more noticeable with the mRNA COVID-19 vaccine, while injection site reactogenicity events were more prevalent with the influenza vaccine. Compared to the influenza vaccine, mRNA COVID-19 vaccines demonstrated a significantly higher risk for a few manageable cardiovascular complications, such as hypertensive crisis (adjusted reporting odds ratio [ROR], 12.72; 95% confidence interval [CI], 2.47-65.54), and supraventricular tachycardia (adjusted ROR, 7.94; 95% CI, 2.62-24.00), but lower risk of neurological complications such as syncope, neuralgia, loss of consciousness, Guillain-Barre syndrome, gait disturbance, visual impairment, and dyskinesia. This study has not identified significant safety concerns regarding mRNA vaccination in real-world settings. The overall safety profile patterned a lower risk of serious AEFI following mRNA vaccines compared to influenza vaccines.