Project description:The surgical management of truncus arteriosus poses a constant challenge for the cardiac team treating the patient. A correct diagnosis, surgical therapy and post-operative management are crucial for the survival of the patient. Almost 30% of the patients show an abnormal number of leaflets in the truncal valve (TV), the majority being quadricuspid valves. Additionally, around 25% of the patients show some degree of TV incompetence. We demonstrate an effective way to reconstruct incompetent, quadricuspid valves with good post-operative outcome.
Project description:Among valve-sparing aortic root replacement techniques developed for the treatment of aortic root aneurysms and aortic insufficiency, the reimplantation technique (the David procedure) has proved to provide excellent outcomes in experienced hands. However, it involves certain challenges in technical standardization, particularly for graft sizing, which is still far from standardization. A novel device was developed to facilitate and provide all the measurements in high precision and accuracy required for the David procedure. The device allows easy, rapid, and accurate acquisition of the patient"s data and appropriate configuration of the aortic valve, irrespective of the surgeon's subjective evaluations. This all-in-one device provides all the major parameters including graft size, effective height, graft preparation, and simulation of the aortic coaptation. The device was successfully tested on a Devotini aortic root simulator and on a bovine heart ex vivo. The device proposed herein to be used for reimplantation has one explicit advantage: all valve geometry to be reconstructed and repaired can be simulated on the device with all its elements, in particular, the commissures and the cusps. Thus, all that is necessary can be clearly visualized in a manner whatever the configuration the surgeon prefers, particularly the creation of the effective height.
Project description:Quadricuspid aortic valves are rare congenital anomalies which can be diagnosed by various imaging modalities. Described is the case of a 77 year old female with a quadricuspid aortic valve diagnosed by cardiac CT.
Project description:Quadricuspid aortic valve (QAV) is a rare congenital cardiac anomaly causing aortic regurgitation usually in the fifth to sixth decade of life. Earlier, the diagnosis was mostly during postmortem or intraoperative, but now with the advent of better imaging techniques such as transthoracic echocardiography, transesophageal echocardiography (TEE), and cardiac magnetic resonance imaging, more cases are being diagnosed in asymptomatic patients. We present a case of a 39-year-old male who was found to have QAV, with the help of TEE, while undergoing evaluation for a diastolic murmur. The patient was found to have Type B QAV with moderate aortic regurgitation. We also present a brief review of classification, pathophysiology, and embryological basis of this rare congenital anomaly. The importance of diagnosing QAV lies in the fact that majority of these patients will require surgery for aortic regurgitation and close follow-up so that aortic valve replacement/repair is done before the left ventricular decompensation occurs.
Project description:Coronary artery obstruction is an uncommon yet devastating complication of transcatheter aortic valve replacement (TAVR) and may necessitate leaflet modification. A 38-year-old man presented to our center with quadricuspid aortic valve with severe aortic regurgitation. Double leaflet modification was performed with the Bioprosthetic or native Aortic Scallop Intentional Laceration to prevent Iatrogenic Coronary Artery obstruction (BASILICA) technique prior to TAVR, creating 6 leaflets from 4. The patient tolerated the procedure well with symptomatic improvement. Follow-up transthoracic echocardiogram showed normal bioprosthetic aortic valve function. This case demonstrates feasibility of this procedure with comprehensive preprocedural analysis and intraprocedural imaging guidance.
Project description:BackgroundQuadricuspid aortic valve (QAV) is a rare congenital malformation that can present with aortic regurgitation or aortic stenosis (AS)), requiring surgical treatment. Transcatheter aortic valve replacement (TAVR) is an alternative treatment for older patients and its prognosis for QAV therapy remains challenging. We sought to examine our early experience with TAVR in patients with QAV.Materials and methodsProspectively collected data were retrospectively reviewed in patients with QAV undergoing TAVR in our institution.ResultsFive patients with QAV and AR or AS were treated with TAVR between January 2016 and January 2022. The mean age was 73.8 years (range 69-82 years), and the median Society of Thoracic Surgeons score was 7.51% (range 2.668-18.138%). Two patients had type B and three had either type A, D, or F according to the Hurwitz and Roberts classification for QAV. Four patients with pure aortic regurgitation underwent transapical TAVR using the J-Valve system, and the patient with severe AS underwent transfemoral TAVR using the Venus-A system. Procedural success was achieved in all five patients. Trivial paravalvular leak was only detected in one case after the procedure, and one patient received a permanent pacemaker due to high-degree atrioventricular block three days later. The median follow-up period was 18 (12-56) months. After discharge, no deaths occurred during the 1 year follow-up. All patients improved by ≥1 New York Heart Association functional class at 30 days; four patients were in functional class ≤II later in the follow-up period. All patients' heart failure symptoms improved considerably.ConclusionOur early experience with TAVR in QAV demonstrates these procedures to be feasible with acceptable early results. Further follow-up is necessary to determine the long-term outcomes of this modality.Clinical trial registration[ClinicalTrials.gov], identifier [NCT02917980].