Peer video feedback builds basic life support skills: A randomized controlled non-inferiority trial.


ABSTRACT:

Introduction

Training Basic Life Support saves lives. However, current BLS training approaches are time-consuming and costly. Alternative cost-efficient and effective training methods are highly needed. The present study evaluated whether a video-feedback supported peer-guided Basic Life Support training approach achieves similar practical performance as a standard instructor-guided training in laypersons.

Methods

In a randomized controlled non-inferiority trial, 288 first-year medical students were randomized to two study arms with different Basic Life Support training methods: 1) Standard Instructor Feedback (SIF) or 2) a Peer Video Feedback (PVF). Outcome parameters were objective data for Basic Life Support performance (compression depth and rate) from a resuscitation manikin with recording software as well as overall Basic Life Support performance and subjective confidence. Non-inferiority margins (Δ) for these outcome parameters and sample size calculation were based on previous studies with Standard Instructor Feedback. Two-sided 95% confidence intervals were employed to determine significance of non-inferiority.

Results

Results confirmed non-inferiority of Peer Video Feedback to Standard Instructor Feedback for compression depth (proportion difference PVF-SIF = 2.9%; 95% CI: -8.2% to 14.1%; Δ = -19%), overall Basic Life Support performance (proportion difference PVF-SIF = 6.7%; 95% CI: 0.0% to 14.3%; Δ = -27%) and subjective confidence for CPR performance (proportion difference PVF-SIF = -0.01; 95% CI: -0.18-0.17; Δ = -0.5) and emergency situations (proportion difference PVF-SIF = -0.02; 95% CI: -0.21-0.18; Δ = -0.5). Results for compression rate were inconclusive.

Discussion

Peer Video Feedback achieves comparable results as standard instructor-based training methods. It is an easy-to-apply and cost-efficient alternative to standard Basic Life Support training methods. To improve performance with respect to compression rate, additional implementation of a metronome is recommended.

SUBMITTER: Sopka S 

PROVIDER: S-EPMC8297748 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC9134732 | biostudies-literature
| S-EPMC5997099 | biostudies-literature
| S-EPMC9315691 | biostudies-literature
| S-EPMC7022135 | biostudies-literature
| S-EPMC6127933 | biostudies-literature
| S-EPMC10496316 | biostudies-literature
| S-EPMC3353161 | biostudies-other
| S-EPMC5523086 | biostudies-literature
| S-EPMC4978818 | biostudies-literature
| S-EPMC6006697 | biostudies-literature