Project description:OBJECTIVES:To evaluate the influence of baseline parameters on the occurrence of stent-graft surface movement after endovascular aneurysm repair (EVAR) and to investigate its association with migration and stent-graft-related endoleaks (srEL). METHODS:In this retrospective, cross-sectional study, three-dimensional surface models of the stent-graft, delimited by landmarks using custom-built software, were derived from the pre-discharge and last follow-up computed tomography angiography (CTA). Stent-graft surface movement in the proximal anchoring zone between these examinations was considered significant at a threshold of 9 mm. The Cox proportional hazards model was used to determine baseline variables associated with the occurrence of stent-graft surface movement. The association between migration and srEL with stent-graft surface movement was tested with the chi-square and the Fisher exact test, respectively. RESULTS:Stent-graft surface movement was observed in 54 (28.9%) of 187 patients. Multivariate analysis revealed that age ([HR] 1.05; p?=?0.017), proximal neck diameter ([HR] 5.07; p?<?0.001), infrarenal aortic neck angulation ([HR] 1.02, p?=?0.002), and proximal neck length ([HR] 0.62, p?<?0.001) were significantly associated with the occurrence of stent-graft surface movement. Migration and srEL occurred in 17 (31.5%) and 5 (9.3%) patients, with and 11 (8.3%) and 2 (1.5%) without stent-graft surface movement (p?<?0.001, p?=?0.022). CONCLUSIONS:Age, neck diameter, infrarenal neck angulation, and proximal neck length were significantly associated with the occurrence of stent-graft surface movement. Apart from possible use of adjunctive sealing systems, concerned patients may benefit from regular CTA surveillance, enabling timely diagnosis of subtle changes of stent-graft position. KEY POINTS:• Stent-graft surface movement, demonstrating subtle, three-dimensional changes in stent-graft position in the proximal anchoring zone, can be derived from CTA examinations. • Age, proximal neck diameter, and infrarenal neck angulation were significantly associated with an increased incidence of stent-graft surface movement. Stent-graft surface movement is significantly more frequent in patients with stent-graft migration and stent-graft-related endoleaks. • Consideration of risk factors for stent-graft surface movement may help to identify patients who might benefit from regular CTA surveillance and timely diagnosis of subtle changes of stent-graft position, enabling re-interventions to prevent migration and srEL.
Project description:PurposeTo assess outcomes of a low-profile thoracic stent-graft in the treatment of thoracic aortic pathologies.MethodsA retrospective analysis of all consecutive patients with aortic thoracic pathologies treated with the RelayPro device in two university hospitals between October 2018 and July 2019.Results23 patients (65% men; mean age 63.4 ± 15 years) were treated. Pathologies included aortic dissections (n = 10), 5 residual type A (22%) and 5 type B (22%), 6 degenerative aortic aneurysms (26%), 4 penetrating aortic ulcers (17%), and aortic erosion, intramural hematoma and aortic rupture (n = 1 and 4% in each case). Two cases (9%) were emergent and two urgent. Proximal landing was achieved in zones 0 (4%), 1 (4%), 2 (43%), and 3 (26%). Five grafts were frozen elephant trunk extensions. Technical success was 100% with accurate device deployment in the intended landing zone of the aortic arch in all 23 patients and with no Ia/III endoleaks and three (13%) type II endoleaks. Apposition was adequate in 96%. Two patients had post-implantation syndromes (one fever, one leukocytosis). Mean follow-up was 11.6 ± 3.7 months (range, 2-16) with no other complications, secondary interventions or conversions to open surgery. There was no 30-day mortality and no aortic-related mortality; all-cause mortality was 4% during follow-up.ConclusionA 3-4 French reduced profile in the current generation of stent-grafts facilitates TEVAR particularly in patients with smaller vessels access. Early safety and effectiveness outcomes are favorable, even in endpoints such as deployment accuracy and apposition which may be surrogates for longer-term clinical success and durability.
Project description:Endovascular repair has been introduced to decrease the morbidity and mortality associated with open surgical repair of aortic arch pathology. We illustrate total percutaneous transfemoral approach with a 3-vessel inner branch stent-graft to treat aortic arch aneurysm. (Level of Difficulty: Advanced.) Graphical abstract
Project description:Pulmonary pseudoaneurysms have various causes and typically arise from the main pulmonary artery. Surgical and endovascular options may be considered for treatment. We report the case of a man with a pseudoaneurysm arising from the right pulmonary artery, treated with a septal occlusion device and percutaneous thrombin injection. (Level of Difficulty: Advanced.).
Project description:A 79-year-old woman was admitted with a large chronic dissecting ascending aortic aneurysm starting 5 mm distal to the ostia of the left coronary artery and ending immediately proximal to the innominate artery. A reverse extra-anatomic aortic arch debranching procedure was performed. During the same operative time, through a transapical approach, a thoracic stent graft was deployed with the proximal landing zone just distal to the coronary ostia and the distal landing zone excluding the origin of the left common carotid artery. The postoperative course was uneventful. Computed tomography at 12 months documented patent extra-anatomic aortic arch debranching and no evidence of endoleak.
Project description:Objective/backgroundThe purpose of this report is to demonstrate a novel endovascular technique for gaining and producing the maximal landing zone for a thoracic stent graft in a patient with a chronic type B aortic dissection.MethodsThe patient was a 64 year old man with chronic type B aortic dissection. He had developed acute type B aortic dissection and undergone descending thoracic replacement (Zone 2-Th10) 12 years earlier. During follow-up, he developed an anastomotic false aneurysm distally. In the initial operation, the distal anastomosis was performed with fenestration of the dissecting membrane. Computed tomography showed a pseudoaneurysm of 54 mm that was positioned 9 cm proximal to the coeliac artery. The landing zone was < 20 mm in the fenestrated area. At surgery, the true and false lumens were each cannulated from the femoral artery, and a pull through form was made just above the fenestrated flap. After the wire exchange, a 4 mm cutting balloon was positioned on the bottom of the flap, and the flap was gently sawed about 3.5 cm.ResultsAfter stent graft placement no endoleak was observed. The patient was discharged without any complications.ConclusionThis technique was effective in producing a sufficient landing zone for endovascular aortic repair in a patient with an anastomotic pseudoaneurysm of chronic type B aortic dissection.
Project description:BackgroundThe Food and Drug Administration has approved devices for endovascular management of thoracic endovascular aortic aneurysm repair (TEVAR); however, limited data exist describing the outcomes of TEVAR for aneurysms attributable to chronic type B aortic dissection (cTBAD). This study was undertaken to determine the results of endovascular treatment of cTBAD with aneurysmal degeneration.MethodsA retrospective analysis of all patients treated for cTBAD with aneurysmal degeneration at the University of Florida from 2004 to 2011 was performed. Computed tomograms with centerline reconstruction were analyzed to determine change in aortic diameter, relative proportions of aortic treatment lengths, and false lumen perfusion status. Reintervention and mortality were estimated using life-tables. Cox regression analysis was completed to predict mortality.ResultsEighty patients underwent TEVAR for aneurysm due to cTBAD (mean age [± standard deviation], 60 ± 13 years [male, 87.5%; n = 70]; median follow-up, 26 [range, 1-74] months). Median time from diagnosis of TBAD to TEVAR was 16 (range, 1-72) months. Prior aortic root/arch replacement had been performed in 29% (n = 23) at a median interval of 28.5 (range, 0.5-312) months. Mean preoperative aneurysm diameter was 62.0 ± 9.9 mm. In 75% (n = 60) of cases, coverage was proximal to zone 3, and 24% (n = 19) underwent carotid-subclavian bypass or other arch debranching procedure. Spinal drains were used in 78% (pre-op 71%, n = 57; post-op 6%, n = 5). Length of stay was 6.5 ± 4.7 days with a composite morbidity of 26% and in-hospital mortality of 2.5% (n = 2). Overall neurologic event rate was 17% (spinal cord ischemia 10% [n = 8], with a permanent deficit observed in 6.2% [n = 5]; stroke 7.5%). Aneurysm diameter reduced or stabilized in 65%. The false lumen thrombosed completely within the thoracic aorta in 52%, and reintervention within the treated aortic segment was required in 16% (n = 13).One- and 3-year freedom from reintervention (with 95% confidence interval [CI]) was 80% (range, 68%-88%) and 70% (range, 57%-80%), respectively. Survival at 1 and 5 years was 89% (range, 80%-94%) and 70% (range, 55%-81%) and was not significantly different among patients requiring reintervention or experiencing favorable aortic remodeling. Multivariable analysis identified coronary artery disease (hazard ratio [HR], 6.4; 95% CI, 2.3-17.7; P < .005), prior infrarenal aortic surgery (HR, 8.6; 95% CI, 2.3-31.7; P = .001), and congestive heart failure (HR, 11.9; 95% CI, 1.9-73.8; P = .008) as independent risk factors for mortality. Hyperlipidemia was found to be protective (HR, 0.2; 95% CI, 0.05-0.6; P = .004). No significant difference in predictors of mortality were found between patients who underwent reintervention vs those who did not (P = .2).ConclusionsTEVAR for cTBAD with aneurysmal degeneration can be performed safely but spinal cord ischemia rates may be higher than previously reported. Liberal use of procedural adjuncts to reduce this complication, such as spinal drainage, is recommended. Reintervention is common, but long-term survival does not appear to be impacted by remediation.
Project description:OBJECTIVE:This study explored the clinical efficacy and hemodynamic effects of the micropore stent graft (MSG) that could promote aortic remodeling and preserve important organ branches. METHODS:We conducted a retrospective analysis of 26 patients who underwent endovascular repair using an MSG for DeBakey types I and III TAD at our center between December 2014 and December 2017. The main efficacy parameters were rupture of the false lumen or dissection-related death, conversion to open repair, secondary reintervention, branch vessel patency, and the hemodynamic effects of TAD at 12 months. RESULTS:Dissection rupture, dissection-related mortality, conversion to open repair, and secondary reintervention rates at 12 months were 0, 3.9, 0, and 0%, respectively. In the 24 patients with more than 6 months of follow-up, micropore stents were implanted to cover 39 openings in aortic arch branches, 91.7% (22/24) presented with complete thrombosis in the false lumen, 8.3% (2/24) presented with partial thrombosis in the false lumen, 35.2% (6/17) presented with a thrombus in the false lumen that was completely absorbed, and all 39 branches were patent. After surgery, pressure peak value and fluctuation along with the degree and range of unstable blood flow in the aortic lumen decreased. CONCLUSIONS:For type I and type III thoracic artic dissection, endovascular treatment with an MSG may be a safe and effective treatment option with a good midterm outcome.
Project description:Consideration for oversizing the proximal stent graft is suggested in endovascular aortic repair. However, a special recommendation for the proximal oversizing ratio (OSR) in patients with ruptured abdominal aortic aneurysm (rAAA) is ambiguous. This study aims to evaluate the effect of different degrees of the proximal oversizing ratio (OSR) on risk of type IA endoleak (TIAEL) in hemodynamically stable and unstable patients with rAAA undergoing emergency endovascular aortic repair (EVAR). Our study included 134 rAAA patients undergoing emergent EVAR, and we did not observe a significant association between hemodynamic instability and risk of T1AEL (HR 3.89, 95%CI 0.40-37.75, p = 0.24). All three T1AELs in the hemodynamically unstable subgroup were observed in patients with OSR ≤ 30%, but no significant difference was found regarding T1AEL between patients with OSR > 30% and OSR ≤ 30% (0.00% vs. 11.11%, p = 0.19). As for hemodynamically stable patients, OSR > 20% was associated with a significantly decreased risk of T1AEL (HR 0.03, 95%CI 0.01-0.53, p = 0.016). In conclusion, a proximal OSR > 20% is associated with a decreased risk of T1AEL in hemodynamically stable patients, while an OSR > 30% did not add an additional advantage of lowering the risk of T1AEL in hemodynamically unstable patients.