Selective Laser Trabeculoplasty Versus MIGS: Forgotten Art or First-Step Procedure in Selected Patients with Open-Angle Glaucoma.


ABSTRACT:

Introduction

To evaluate the long-term effect on intraocular pressure (IOP) and glaucoma medication of selective laser trabeculoplasty (SLT) compared to minimally invasive glaucoma surgery (MIGS) in primary open-angle glaucoma (POAG) and its potential in clinical practice.

Methods

A total of 342 consecutive patients (stand-alone procedures) were included. One hundred and five patients underwent SLT treatment (360° SLT, 95-105 spots, Trabeculas SLT ARCLaser, Nürnberg, DE), 107 patients had an ab interno-derived trabeculotomy (Trabectome®, NeoMedix, Tustin, USA), and 130 patients received iStent inject® implantation (2 implants-Glaukos, CA, USA). IOP and glaucoma therapy were evaluated preoperatively, 1 day, 6 weeks, 3 months, 6 months, and 1, 2, and 3 years postoperatively. Statistical analysis was performed using a regression model and propensity matching score (reduced cohort number) using SPSS v20.0. Kaplan-Meier analysis was included using the following six criteria: criterion A (IOP ≤ 21 mmHg with or without medication, qualified success), criterion B (IOP ≤ 18 mmHg with or without medication, qualified success), criterion C (IOP ≤ 21 mmHg without medication, complete success), criterion D (IOP ≤ 18 mmHg without medication, complete success), criterion E (IOP ≤ 21 mmHg and IOP reduction > 20% after therapy), and criterion F (IOP ≤ 18 mmHg and IOP reduction > 20% after therapy).

Results

In the matched cohort, the SLT cohort showed an IOP reduction of 31.2% from 19.9 ± 2.3 to 13.7 ± 2.7 mmHg (p < 0.001) 3 years postoperatively; in Trabectome® IOP decreased by 31.4% from 20.5 ± 1.3 to 13.8 ± 2.0 mmHg (p < 0.001) and in iStent inject® by 29.9% from 19.5 ± 2.0 to 13.8 ± 2.7 mmHg (p < 0.001). Trabectome® and iStent inject® could not demonstrate a significant reduction in glaucoma therapy (Trabectome® p = 0.138, iStent inject® p = 0.612); a significant drop was noted in SLT (2.2 ± 1.2 to 1.7 ± 1.2, p = 0.046). SLT and MIGS achieved good to moderate survival rates using criterion A (93.3% SLT, 79.7% Trabectome®, 77.6% iStent inject®) and criterion B (74.5% SLT, 48.0% Trabectome®, 56.2% iStent inject®). As expected, low survival rates were obtained with non-filtering procedures: criterion C 11.1% in SLT, 6.5% in Trabectome®, 7.0% in iStent inject® and criterion D 3.0% in SLT, 4.3% in Trabectome®, 3.7% in iStent inject® in 3-year follow-up.

Conclusion

The SLT is a low-complication and effective method for reducing pressure in mild to moderate POAG. SLT is suitable as an initial procedure when setting up a step scheme; MIGS is the treatment of choice as a follow-up for mild to moderate forms of glaucoma and accepted topical therapy. Ethic approval had been given by the Ethikkommission Charité - Universitätsmedizin Berlin, EA4/047/20-retrospectively registered.

SUBMITTER: Pahlitzsch M 

PROVIDER: S-EPMC8319229 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC6124459 | biostudies-literature
| S-EPMC9361429 | biostudies-literature
| S-EPMC3868565 | biostudies-literature
| S-EPMC6610644 | biostudies-literature
| S-EPMC8347751 | biostudies-literature
| S-EPMC3890760 | biostudies-other
| S-EPMC9763163 | biostudies-literature
| S-EPMC5574616 | biostudies-literature
| S-EPMC6170666 | biostudies-literature
| S-EPMC5705413 | biostudies-literature