Extended short-range airborne transmission of respiratory infections.


ABSTRACT: Debate and scientific inquiries regarding airborne transmission of respiratory infections such as COVID-19 and influenza continue. Health authorities including the WHO and the US CDC have recognized the airborne transmission of COVID-19 in specific settings, although the ventilation requirements remain to be determined. In this work we consider the long-range airborne transmission as an extended short-range airborne route, which reconciles the link between short- and long-range airborne routes. The effective short-range distance is defined as the distance in short range at which long-range route has the same volumetric exposure value as that due to short-range route. Our data show that a decrease in ventilation rate or room volume per person, or an increase in the ratio of the number of infected to susceptible people reduces the effective short-range distance. In a normal breathing scenario with one out of five people infected and a room volume of 12 m3 per person to ensure an effective short-range distance of 1.5 m, a ventilation rate of 10 L/s per person is needed for a duration of 2 h. Our results suggest that effective environmental prevention strategies for respiratory infections require appropriate increases in the ventilation rate while maintaining a sufficiently low occupancy. PRACTICAL IMPLICATIONS: Demonstration of the long-range airborne route as an extended short-range airborne route suggests the significant role played by building ventilation in respiratory infection exposure. The reconciliation of short- and long-range airborne transmission suggests that the commonly observed dominance of close-contact transmission is a probable evidence of short-range airborne transmission, following a separate earlier study that revealed the relative insignificance of large droplet transmission in comparison with the short-range airborne-route. Existing ventilation standards do not account for respiratory infection control, and this study presents a possible approach to account for infection under new ventilation standards.

SUBMITTER: Chen W 

PROVIDER: S-EPMC8342890 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC8652937 | biostudies-literature
| S-EPMC9085449 | biostudies-literature
| S-SCDT-10_15252-EMMM_202317932 | biostudies-other
| S-EPMC10701621 | biostudies-literature
| S-EPMC8231662 | biostudies-literature
| S-EPMC6731521 | biostudies-literature
| S-EPMC9782262 | biostudies-literature
| S-EPMC7470989 | biostudies-literature
| S-EPMC8410799 | biostudies-literature
| S-EPMC8487323 | biostudies-literature