Project description:The antigen rapid diagnostic test (Ag-RDT) is a useful diagnostic tool for the detection and management of COVID-19 spread. Global SARS-CoV-2 variant outbreaks have highlighted the need for a test capable of detecting SARS-CoV-2 variants with high sensitivity and a low limit of detection. This study aimed to develop and evaluate, both analytically and clinically, an antigen rapid diagnostic test (the KestrelTM COVID-19 Ag Rapid Test) for professional use. A lateral flow immunoassay-based diagnostic test kit was developed, and various aspects of its analytical performance were evaluated. This test kit was clinically evaluated by two independent laboratories and showed closely related results of 96.49% and 98.33% of sensitivity, 100% and 100% of specificity, and 99.01% and 99.44% of accuracy, respectively. A limit of detection was observed at values as low as 0.156 ng/mL for recombinant SARS-CoV-2 nucleocapsid protein. Moreover, the test kit successfully detected the recombinant SARS-CoV-2 nucleocapsid protein (NP) of wild-type, Alpha-, Beta-, Gamma-, Delta-, Epsilon-, Kappa-, and Omicron-variants as positive results. Therefore, the KestrelTM COVID-19 Ag Rapid Test may have potential use for effective COVID-19 screening, surveillance, and infection control in a variety of global SARS-CoV-2 variant outbreaks.
Project description:Coronavirus disease 2019, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), poses a considerable threat to global public health. This study developed and evaluated a rapid, low-cost, expandable, and sequencing-free high-resolution melting (HRM) assay for the direct detection of SARS-CoV-2 variants. A panel of 64 common bacterial and viral pathogens that can cause respiratory tract infections was employed to evaluate our method's specificity. Serial dilutions of viral isolates determined the sensitivity of the method. Finally, the assay's clinical performance was assessed using 324 clinical samples with potential SARS-CoV-2 infection. Multiplex HRM analysis accurately identified SARS-CoV-2 (as confirmed with parallel reverse transcription-quantitative PCR [qRT-PCR] tests), differentiating between mutations at each marker site within approximately 2 h. For each target, the limit of detection (LOD) was lower than 10 copies/reaction (the LOD of N, G142D, R158G, Y505H, V213G, G446S, S413R, F486V, and S704L was 7.38, 9.72, 9.96, 9.96, 9.50, 7.80, 9.33, 8.25, and 8.25 copies/reaction, respectively). No cross-reactivity occurred with organisms of the specificity testing panel. In terms of variant detection, our results had a 97.9% (47/48) rate of agreement with standard Sanger sequencing. The multiplex HRM assay therefore offers a rapid and simple procedure for detecting SARS-CoV-2 variants. IMPORTANCE In the face of the current severe situation of increasing SARS-CoV-2 variants, we developed an upgraded multiplex HRM method for the predominant SARS-CoV-2 variants based on our original research. This method not only could identify the variants but also could be utilized in subsequent detection of novel variants since the assay has great performance in terms of flexibility. In summary, the upgraded multiplex HRM assay is a rapid, reliable, and economical detection method, which could better screen prevalent virus strains, monitor the epidemic situation, and help to develop measures for the prevention and control of SARS-CoV-2.
Project description:ObjectivesEmerging severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variant strains can be associated with increased transmissibility, more severe disease, and reduced effectiveness of treatments. To improve the availability of regional variant surveillance, we describe a variant genotyping system that is rapid, accurate, adaptable, and able to detect new low-level variants built with existing hospital infrastructure.MethodsWe used a tiered high-throughput SARS-CoV-2 screening program to characterize variants in a supraregional health system over 76 days. Combining targeted reverse transcription-polymerase chain reaction (RT-PCR) and selective sequencing, we screened SARS-CoV-2 reactive samples from all hospitals within our health care system for genotyping dominant and emerging variants.ResultsThe median turnaround for genotyping was 2 days using the high-throughput RT-PCR-based screen, allowing us to rapidly characterize the emerging Delta variant. In our population, the Delta variant is associated with a lower cycle threshold value, lower age at infection, and increased vaccine-breakthrough cases. Detection of low-level and potentially emerging variants highlights the utility of a tiered approach.ConclusionsThese findings underscore the need for fast, low-cost, high-throughput monitoring of regional viral sequences as the pandemic unfolds and the emergence of SARS-CoV-2 variants increases. Combining RT-PCR-based screening with selective sequencing allows for rapid genotyping of variants and dynamic system improvement.
Project description:The SARS-CoV-2 virus is continuously evolving, with appearance of new variants characterized by multiple genomic mutations, some of which can affect functional properties, including infectivity, interactions with host immunity, and disease severity. The rapid spread of new SARS-CoV-2 variants has highlighted the urgency to trace the virus evolution, to help limit its diffusion, and to assess effectiveness of containment strategies. We propose here a PCR-based rapid, sensitive and low-cost allelic discrimination assay panel for the identification of SARS-CoV-2 genotypes, useful for detection in different sample types, such as nasopharyngeal swabs and wastewater. The tests carried out demonstrate that this in-house assay, whose results were confirmed by SARS-CoV-2 whole-genome sequencing, can detect variations in up to 10 viral genome positions at once and is specific and highly sensitive for identification of all tested SARS-CoV-2 clades, even in the case of samples very diluted and of poor quality, particularly difficult to analyze.
Project description:Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) has been identified as the causative agent of coronavirus disease 2019 and is capable of human-to-human transmission and rapid global spread. The rapid emergence and global spread of SARS-CoV-2 has encouraged the establishment of a rapid, sensitive, and reliable viral detection and quantification methodology. Here, we present an alternative assay, termed immuno-plaque assay (iPA), which utilizes a combination of plaque assay and immunofluorescence techniques. We have extensively optimized the conditions for SARS-CoV-2 infection and demonstrated the great flexibility of iPA detection using several antibodies and dual-probing with two distinct epitope-specific antibodies. In addition, we showed that iPA could be utilized for ultra-high-throughput viral titration and neutralization assay within 24 h and is amenable to a 384-well format. These advantages will significantly accelerate SARS-CoV-2 research outcomes during this pandemic period.
Project description:Emerging SARS-CoV-2 (SC-2) variants with increased infectivity and vaccine resistance are of major concern. Rapid identification of such variants is important for the public health decision making and to provide valuable data for epidemiological and policy decision making. We developed a multiplex reverse transcriptase quantitative PCR (RT-qPCR) assay that can specifically identify and differentiate between the emerging B.1.1.7 and B.1.351 SC-2 variants. In a single assay, we combined four reactions-one that detects SC-2 RNA independently of the strain, one that detects the D3L mutation, which is specific to variant B.1.1.7, one that detects the 242 to 244 deletion, which is specific to variant B.1.351, and the fourth reaction, which identifies the human RNAseP gene, serving as an endogenous control for RNA extraction integrity. We show that the strain-specific reactions target mutations that are strongly associated with the target variants and not with other major known variants. The assay's specificity was tested against a panel of respiratory pathogens (n = 16), showing high specificity toward SC-2 RNA. The assay's sensitivity was assessed using both in vitro transcribed RNA and clinical samples and was determined to be between 20 and 40 viral RNA copies per reaction. The assay performance was corroborated with Sanger and whole-genome sequencing, showing complete agreement with the sequencing results. The new assay is currently implemented in the routine diagnostic work at the Central Virology Laboratory, and may be used in other laboratories to facilitate the diagnosis of these major worldwide-circulating SC-2 variants. IMPORTANCE This study describes the design and utilization of a multiplex reverse transcriptase quantitative PCR (RT-qPCR) to identify SARS-COV-2 (SC2) RNA in general and, specifically, to detect whether it is of lineage B.1.1.7 or B.1.351. Implementation of this method in diagnostic and research laboratories worldwide may help the efforts to contain the COVID-19 pandemic. The method can be easily scaled up and be used in high-throughput laboratories, as well as small ones. In addition to immediate help in diagnostic efforts, this method may also help in epidemiological studies focused on the spread of emerging SC-2 lineages.
Project description:Background and aimSARS-CoV-2 quick testing is relevant for the containment of new pandemic waves. Antigen testing in self-collected saliva might be useful. We compared salivary and naso-pharyngeal swab (NPS) SARS-CoV-2 antigen detection by a rapid chemiluminescent assay (CLEIA) and two different point-of-care (POC) immunochromatographic assays, with results of molecular testing.Methods234 patients were prospectively enrolled. Paired self-collected saliva (Salivette) and NPS were obtained to perform rRT-PCR, chemiluminescent (Lumipulse G) and POC (NPS: Fujirebio and Abbott; saliva: Fujirebio) for SARS-CoV-2 antigen detection.ResultsThe overall agreement between NPS and saliva rRT-PCR was 78.7%, reaching 91.7% at the first week from symptoms. SARS-CoV-2 CLEIA antigen was highly accurate in distinguishing positive and negative NPS (ROC-AUC = 0.939, 95%CI:0.903-0.977), with 81.6% sensitivity and 93.8% specificity. This assay on saliva reached the optimal value within 7 days from symptoms onset (Sensitivity: 72%; Specificity: 97%). Saliva POC antigen was limited in sensitivity (13%), performing better in NPS (Sensitivity: 48% and 66%; Specificity: 100% and 99% for Espline and Abbott respectively), depending on viral loads.ConclusionsSelf-collected saliva is a valid alternative to NPS for SARS-CoV-2 detection by molecular, but also by CLEIA antigen testing, which is therefore potentially useful for large scale screening.
Project description:Since autumn 2020, rapid antigen tests (RATs) have been implemented in several countries as an important pillar of the national testing strategy to rapidly screen for infections on site during the SARS-CoV-2 pandemic. The current surge in infection rates around the globe is driven by the variant of concern (VoC) omicron (B.1.1.529). Here, we evaluated the performance of nine SARS-CoV-2 RATs in a single-centre laboratory study. We examined a total of 115 SARS-CoV-2 PCR-negative and 166 SARS-CoV-2 PCR-positive respiratory swab samples (101 omicron, 65 delta (B.1.617.2)) collected from October 2021 until January 2022 as well as cell culture-expanded clinical isolates of both VoCs. In an assessment of the analytical sensitivity in clinical specimen, the 50% limit of detection (LoD50) ranged from 1.77 × 106 to 7.03 × 107 RNA copies subjected to the RAT for omicron compared to 1.32 × 105 to 2.05 × 106 for delta. To score positive in these point-of-care tests, up to 10-fold (LoD50) or 101-fold (LoD95) higher virus loads were required for omicron- compared to delta-containing samples. The rates of true positive test results for omicron samples in the highest virus load category (Ct values < 25) ranged between 31.4 and 77.8%, while they dropped to 0-8.3% for samples with intermediate Ct values (25-30). Of note, testing of expanded virus stocks suggested a comparable RAT sensitivity of both VoCs, questioning the predictive value of this type of in vitro-studies for clinical performance. Given their importance for national test strategies in the current omicron wave, awareness must be increased for the reduced detection rate of omicron infections by RATs and a short list of suitable RATs that fulfill the minimal requirements of performance should be rapidly disclosed.
Project description:BackgroundSARS-CoV-2 antigen-based tests are well-calibrated to infectiousness and have a critical role to play in the COVID-19 public health response. We report the development and performance of a unique lateral flow immunoassay (LFA).MethodsCombinations of several monoclonal antibodies targeting multiple antigenic sites on the SARS-CoV-2 nucleocapsid protein (NP) were isolated, evaluated, and chosen for the development of a LFA termed CoV-SCAN (BioMedomics, Inc.). Clinical point-of-care studies in symptomatic and asymptomatic individuals were conducted to evaluate positive predictive agreement (PPA) and negative predictive agreement (NPA) with RT-PCR as comparator.ResultsIn laboratory testing, CoV-SCAN detected 14 recombinant N-proteins of SARS-CoV-2 variants with sensitivity in the range of 0.2-3.2 ng/mL, and 10 authentic SARS-CoV-2 variants with sensitivity in the range of 1.6-12.5 TCID50/swab. No cross reactivity was observed with other human coronaviruses or other respiratory pathogens. In clinical point-of-care testing on 148 individuals over age 2 with symptoms of ≤5 days, PPA was 87.2% (CI 95: 78.3-94.8%) and NPA was 100% (CI 95: 94.2-100%). In another 884 asymptomatic individuals, PPA was 85.7% (CI 95: 42.1-99.6%) and 99.7% (99.0-99.9%). Overall, CoV-SCAN detected over 97.2% of specimens with CT values <30 and 93.8% of nasal swab specimens with the Omicron variant, even within the first 2 days after symptom onset.ConclusionsThe unique construction of CoV-SCAN using two pairs of monoclonal antibodies has resulted in a test with high performance that remains durable across multiple variants in both laboratory and clinical evaluations. CoV-SCAN should identify almost all individuals harboring infectious SARS-CoV-2.SummaryUnique construction of a point-of-care rapid antigen test using two pairs of monoclonal antibodies has led to good performance that remained durable across multiple variants in laboratory and clinical evaluations. Test should identify almost all individuals harboring infectious SARS-CoV-2.