Ontology highlight
ABSTRACT: Background
The study aimed to compare the predictive values of the thrombolysis in myocardial infarction (TIMI); History, Electrocardiography, Age, Risk factors and Troponin (HEART) and Global Registry in Acute Coronary Events (GRACE) scoring systems for major adverse cardiovascular events (MACEs) in acute chest pain (ACP) patients admitted to the emergency department (ED).Methods
We systematically searched PubMed, Embase and the Cochrane Library from their inception to June 2020; we compared the following parameters: sensitivity, specificity, positive and negative likelihood ratios (PLR and NLR), diagnostic OR (DOR) and area under the receiver operating characteristic curves (AUC).Results
The pooled sensitivity and specificity for TIMI, HEART and GRACE were 0.95 and 0.36, 0.96 and 0.50, and 0.78 and 0.56, respectively. The pooled PLR and NLR for TIMI, HEART and GRACE were 1.49 and 0.13, 1.94 and 0.08, and 1.77 and 0.40, respectively. The pooled DOR for TIMI, HEART and GRACE was 9.18, 17.92 and 4.00, respectively. The AUC for TIMI, HEART and GRACE was 0.80, 0.80 and 0.70, respectively. Finally, the results of indirect comparison suggested the superiority of values of TIMI and HEART to those of GRACE for predicting MACEs, while there were no significant differences between TIMI and HEART for predicting MACEs.Conclusions
TIMI and HEART were superior to GRACE for predicting MACE risk in ACP patients admitted to the ED.
SUBMITTER: Ke J
PROVIDER: S-EPMC8375746 | biostudies-literature |
REPOSITORIES: biostudies-literature