Vital sign metrics of VLBW infants in three NICUs: implications for predictive algorithms.


ABSTRACT:

Background

Continuous heart rate (HR) and oxygenation (SpO2) metrics can be useful for predicting adverse events in very low birth weight (VLBW) infants. To optimize the utility of these tools, inter-site variability must be taken into account.

Methods

For VLBW infants at three neonatal intensive care units (NICUs), we analyzed the mean, standard deviation, skewness, kurtosis, and cross-correlation of electrocardiogram HR, pulse oximeter pulse rate, and SpO2. The number and durations of bradycardia and desaturation events were also measured. Twenty-two metrics were calculated hourly, and mean daily values were compared between sites.

Results

We analyzed data from 1168 VLBW infants from birth through day 42 (35,238 infant-days). HR and SpO2 metrics were similar at the three NICUs, with mean HR rising by ~10 beats/min over the first 2 weeks and mean SpO2 remaining stable ~94% over time. The number of bradycardia events was higher at one site, and the duration of desaturations was longer at another site.

Conclusions

Mean HR and SpO2 were generally similar among VLBW infants at three NICUs from birth through 6 weeks of age, but bradycardia and desaturation events differed in the first 2 weeks after birth. This highlights the importance of developing predictive analytics tools at multiple sites.

Impact

HR and SpO2 analytics can be useful for predicting adverse events in VLBW infants in the NICU, but inter-site differences must be taken into account in developing predictive algorithms. Although mean HR and SpO2 patterns were similar in VLBW infants at three NICUs, inter-site differences in the number of bradycardia events and duration of desaturation events were found. Inter-site differences in bradycardia and desaturation events among VLBW infants should be considered in the development of predictive algorithms.

SUBMITTER: Zimmet AM 

PROVIDER: S-EPMC8376742 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC8316489 | biostudies-literature
| S-EPMC9188354 | biostudies-literature
| S-EPMC9368366 | biostudies-literature
| S-EPMC8280207 | biostudies-literature
| S-EPMC8886570 | biostudies-literature
| S-EPMC4279070 | biostudies-literature
| S-EPMC8604776 | biostudies-literature
| S-EPMC7818086 | biostudies-literature
| S-EPMC6311539 | biostudies-literature
| S-EPMC7268228 | biostudies-literature