Unknown

Dataset Information

0

Measurement validity of an electronic training device to assess breathing characteristics during inspiratory muscle training in patients with weaning difficulties.


ABSTRACT: Inspiratory muscle training (IMT) improves respiratory muscle function and might enhance weaning outcomes in patients with weaning difficulties. An electronic inspiratory loading device provides valid, automatically processed information on breathing characteristics during IMT sessions. Adherence to and quality of IMT, as reflected by work of breathing and power generated by inspiratory muscles, are related to improvements in inspiratory muscle function in patients with chronic obstructive pulmonary disease. The aim of this study was to investigate the validity of an electronic training device to assess and provide real-time feedback on breathing characteristics during inspiratory muscle training (IMT) in patient with weaning difficulties. Patients with weaning difficulties performed daily IMT sessions against a tapered flow-resistive load of approximately 30 to 50% of the patient's maximal inspiratory pressure. Airflow and airway pressure measurements were simultaneously collected with the training device (POWERbreatheKH2, POWERbreathe International Ltd, UK) and a portable spirometer (reference device, Pocket-Spiro USB/BT100, M.E.C, Belgium). Breath by breath analysis of 1002 breaths of 27 training sessions (n = 13) against a mean load of 46±16% of the patient's maximal inspiratory pressure were performed. Good to excellent agreement (Intraclass correlation coefficients: 0.73-0.97) was observed for all breathing characteristics. When individual differences were plotted against mean values of breaths recorded by both devices, small average biases were observed for all breathing characteristics. To conclude, the training device provides valid assessments of breathing characteristics to quantify inspiratory muscle effort (e.g. work of breathing and peak power) during IMT in patients with weaning difficulties. Availability of valid real-time data of breathing responses provided to both the physical therapist and the patient, can be clinically usefull to optimize the training stimulus. By adapting the external load based on the visual feedback of the training device, respiratory muscle work and power generation during IMT can be maximized during the training.

SUBMITTER: Van Hollebeke M 

PROVIDER: S-EPMC8389486 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC8864155 | biostudies-literature
| S-EPMC11355280 | biostudies-literature
| S-EPMC3219341 | biostudies-literature
| S-EPMC9274399 | biostudies-literature
| S-EPMC9227718 | biostudies-literature
| S-EPMC7831303 | biostudies-literature
| S-EPMC9299221 | biostudies-literature
| S-EPMC6042566 | biostudies-literature
| S-EPMC10578271 | biostudies-literature
| S-EPMC9475163 | biostudies-literature