Project description:ObjectivesTo our knowledge no previous study has assessed the performance of a rapid antigen diagnostic immunoassay (RAD) conducted at the point of care (POC). We evaluated the Panbio™ COVID-19 Ag Rapid Test Device for diagnosis of coronavirus 2019 disease (COVID-19) in symptomatic patients (n = 412) attending primary healthcare centres.MethodsRAD was performed immediately after sampling following the manufacturer's instructions (reading at 15 min). RT-PCRs were carried out within 24 h of specimen collection. Samples displaying discordant results were processed for culture in Vero E6 cells. Presence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in cell cultures was confirmed by RT-PCR.ResultsOut of 412 patients, 43 (10.4%) tested positive by RT-PCR and RAD, and 358 (86.9%) tested negative by both methods; discordant results (RT-PCR+/RAD-) were obtained in 11 patients (2.7%). Overall specificity and sensitivity of rapid antigen detection (RAD) was 100% (95%CI 98.7-100%) and 79.6% (95%CI 67.0-88.8%), respectively, taking RT-PCR as the reference. Overall RAD negative predictive value for an estimated prevalence of 5% and 10% was 99% (95%CI 97.4-99.6%) and 97.9% (95%CI 95.9-98.9), respectively. SARS-CoV-2 could not be cultured from specimens yielding RT-PCR+/RAD- results (n = 11).ConclusionThe Panbio™ COVID-19 Ag Rapid Test Device performed well as a POC test for early diagnosis of COVID-19 in primary healthcare centres. More crucially, the data suggested that patients with RT-PCR-proven COVID-19 testing negative by RAD are unlikely to be infectious.
Project description:BackgroundSince COVID-19 pandemic is a global crisis, tests with high sensitivity and specificity are crucial for the identification and management of COVID-19 patients. There is an urgent need for low-cost rapid antigen COVID-19 test with a good diagnostic performance. Although various antigen rapid detection tests are widely available, strong evidence of their usefulness in clinical practice are still limited. Therefore, our aim was to evaluate clinical performance of STANDARD Q COVID-19 Ag Test (SD Biosensor, Gyeonggi-do, South Korea).MethodsThe performance of the STANDARD Q COVID-19 Ag Test for the detection of SARS-CoV-2 antigen was evaluated in comparison to RT-qPCR results in 120 symptomatic patients (median age 49, IQR 36-70) who presented to health care facility in Novi Sad, Vojvodina, Serbia.ResultsTwenty five out of 120 samples have been tested positive using STANDARD Q COVID-19 Ag Test, and all of them were also positive on RT-qPCR. Overall, the STANDARD Q COVID-19 Ag Test showed sensitivity of 58.1% (95% CI 42.1-73.0) but it was higher in the early days of disease, when the highest viral loads were detected. During the first five days after the symptom onset, the sensitivity ranged from 66.7% to 100% and the pooled accuracy and Kappa values were high (0.92 and 0.852).ConclusionsA strong agreement between performance of STANDARD Q COVID-19 Ag Test and RT-qPCR was observed during the first five days of illness, suggesting that this rapid antigenic test can be very useful for COVID-19 diagnosis in the early phase of disease.
Project description:ObjectivesThere is limited information on the performance of rapid antigen detection (RAD) tests to identify SARS-CoV-2-infected asymptomatic individuals. In this field study, we evaluated the Panbio™ COVID-19 Ag Rapid Test Device (Abbott Diagnostics, Jena, Germany) for this purpose.MethodsA total of 634 individuals (355 female; median age, 37 years; range, 9-87) were enrolled. Two nasopharyngeal swabs were collected from household (n = 338) and non-household contacts (n = 296) of COVID-19 cases. RAD testing was carried out at the point of care. The RT-PCR test used was the TaqPath COVID-19 Combo Kit (Thermo Fisher Scientific, MA, USA).ResultsHousehold contacts were tested at a median of 2 days (range, 1-7) after diagnosis of the index case, whereas non-household contacts (n = 296) were tested at a median of 6 days (range, 1-7) after exposure. In total, 79 individuals (12.4%) tested positive by RT-PCR, of whom 38 (48.1%) yielded positive RAD results. The overall sensitivity and specificity of the RAD test was 48.1% (95% CI 37.4-58.9) and 100% (95% CI 99.3-100), respectively. Sensitivity was higher in household (50.8%; 95% CI 38.9-62.5) than in non-household (35.7%; 95% CI 16.3-61.2%) contacts. Individuals testing positive by RAD test were more likely (p < 0.001) to become symptomatic than their negative counterparts.DiscussionThe Panbio test displays low sensitivity in asymptomatic close contacts of COVID-19 patients, particularly in non-household contacts. Nonetheless, establishing the optimal timing for upper respiratory tract collection in this group seems imperative to pinpoint test sensitivity.
Project description:As we move into the third year with COVID-19, many countries have attempted to manage the disease as an endemic. However, this is limited by the disease’s morbidity and mortality, the emergence of new strains, and the effectiveness of the vaccine. This brief report describes, evaluates, and discusses the implementation of regular antigen rapid tests (ARTs) for COVID-19 in hemodialysis units. We introduced ARTs during the surge in our hemodialysis units. As compliance with the test was mandatory by regulatory requirements, we surveyed patients and caregivers to measure their acceptability, appropriateness, and feasibility of the ART’s implementation. Acceptability measured confidence and level of comfort when performing ART tests, while appropriateness measured the perception of the necessity of ARTs, safety in the dialysis unit with the implementation of ARTs, and understanding using a Likert scale. Feasibility measured the perception of the timely start of dialysis treatment and the convenience of the test. Our survey found that ARTs were acceptable to 98% of patients and caregivers, with the majority reporting no discomfort. The majority of the patients agreed that ARTs were appropriate and feasible. We reported successful ART implementation in a healthcare setting with no false-positive or transmission within the unit during this period. Nevertheless, the long-term implementation outcome will require further evaluation.
Project description:We evaluated the Panbio™ COVID-19 Ag Rapid Test Device as a point-of-care diagnostic tool for COVID-19 in 357 patients at a pediatric emergency department. Thirty-four patients tested positive by reverse transcription polymerase chain reaction, of which 24 were positive by the antigen assay. The sensitivity and specificity of the assay were 70.5% and 100%, respectively.
Project description:COVID-19 diagnostics was quickly ramped up worldwide early 2020 based on the detection of viral RNA. However, based on the scientific knowledge for pre-existing coronaviruses, it was expected that the SARS-CoV-2 RNA will be detected from symptomatic and at significant rates also from asymptomatic individuals due to persistence of non-infectious RNA. To increase the efficacy of diagnostics, surveillance, screening and pandemic control, rapid methods, such as antigen tests, are needed for decentralized testing and to assess infectiousness. A novel automated mariPOC SARS-CoV-2 test was developed for the detection of conserved structural viral nucleocapsid proteins. The test utilizes sophisticated optical laser technology for two-photon excitation and individual detection of immunoassay solid-phase particles. We validated the new method against qRT-PCR. Sensitivity of the test was 100.0% (13/13) directly from nasopharyngeal swab specimens and 84.4% (38/45) from swab specimens in undefined transport mediums. Specificity of the test was 100.0% (201/201). The test's limit of detection was 2.7 TCID50/test. It showed no cross-reactions. Our study shows that the new test can detect infectious individuals already in 20 min with clinical sensitivity close to qRT-PCR. The mariPOC is a versatile platform for syndromic testing and for high capacity infection control screening of infectious individuals.
Project description:BackgroundIsolation of COVID-19 patients is a crucial infection control measure to prevent further SARS-CoV-2 transmission, but determining an appropriate timing to end the COVID-19 isolation is a challenging. We evaluated the performance of the self-test rapid antigen test (RAT) as a potential proxy to terminate the isolation of COVID-19 patients.Materials and methodsSymptomatic COVID-19 patients were enrolled who were admitted to a regional community treatment center (CTC) in Seoul (South Korea). Self-test RAT and the collection of saliva samples were performed by the patients, on a daily basis, until patient discharge. Cell culture and subgenomic RNA detection were performed on saliva samples.ResultsA total of 138 pairs of saliva samples and corresponding RAT results were collected from 34 COVID-19 patients. Positivity of RAT and cell culture was 27% (37/138) and 12% (16/138), respectively. Of the 16 culture-positive saliva samples, seven (43.8%) corresponding RAT results were positive. Using cell culture as the reference standard, the overall percent agreement, percent positive agreement, and percent negative agreement of RAT were 71% (95% CI, 63-78), 26% (95% CI, 12-42), and 82% (95% CI, 76-87), respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of the RAT for predicting culture results were 44% (95% CI, 20-70), 75% (95% CI, 66-82), 18% (95% CI, 8-34), and 91% (95% CI, 84-96), respectively.ConclusionAbout half of the patients who were SARS-CoV-2 positive based upon cell culture results gave negative RAT results. However, the remaining positive culture cases were detected by RAT, and RAT showed relatively high negative predictive value for viable viral shedding.