Project description:Transcatheter aortic valve implantation (TAVI) has emerged as an alternative technique to treating aortic stenosis in patients with high surgical risk. We present a case of a successful transfemoral TAVI in a high-risk patient with an extremely tortuous iliofemoral system and a significant S-type bend in the descending aorta. With careful preprocedure planning and using all the techniques available, TAVI can be performed in the most challenging patients.
Project description:Transcatheter tricuspid valve-in-valve implantation is a critical option in high risk bioprosthetic tricuspid valve dysfunction. In this case report, balloon-expandable transcatheter heart valve was implanted successfully into the tricuspid valve and early thrombosis was managed successfully. (Level of Difficulty: Intermediate.).
Project description:An 80-year-old male underwent a transcatheter aortic valve implantation (TAVI) for severe senile aortic stenosis. Six weeks after the surgery, he was readmitted to our institution because of a high-grade fever. Transesophageal echocardiography revealed thickening of all three leaflets of the aortic prosthesis and mobile mass on the leaflet, and Streptococcus sanguis was identified from his blood culture. Therefore, he was diagnosed with prosthetic valve endocarditis (PVE) and received intensive intravenous antibiotic therapy. Because he did not respond to the pharmacological therapy, surgical aortic valve replacement (AVR) was indicated although it was considered a relatively high-risk procedure. Herein, we report on the successful surgical AVR in this patient using a pericardial valve after removal of the infected prosthetic valve, and discuss some issues related to this rare complication after TAVI. <Learning objective: Transcatheter aortic valve implantation (TAVI) is a highly effective procedure for patients with symptomatic severe aortic stenosis who are at high risk or deemed inoperable. Because it only requires limited surgical invasiveness, the risk of prosthetic valve endocarditis (PVE) after TAVI is thought to be low. However, PVE can occur even early after TAVI. We present our recent such case and discuss some issues related to this rare complication.>.
Project description:BackgroundTranscatheter aortic valve replacement (TAVR) is a viable treatment option for managing aortic prosthetic valve dysfunction. Although the transfemoral approach is the most commonly used and preferred treatment strategy for TAVR, complex vascular access, such as aortic aneurysm, severe tortuosity, and shaggy aorta, is challenging.Case summaryAn 87-year-old man, who underwent surgical aortic valve replacement for aortic stenosis using a 21-mm Carpentier-Edwards Perimount Valve, presented with New York Heart Association functional Class III dyspnoea. He was diagnosed as having severe symptomatic structural valve deterioration of a bioprosthetic aortic valve. Computed tomography revealed a tortuous and shaggy descending aorta with a saccular aneurysm in the aortic arch. Simultaneous transfemoral valve-in-valve TAVR and Zone 2 thoracic endovascular aortic repair (TEVAR) with debranching were successfully performed using a 22-Fr 65-cm sheath. Although the patient developed paraplegia due to transient spinal cord ischaemia associated with TEVAR, he fully recovered with vasopressor therapy.DiscussionTo the best of our knowledge, this is the first report on simultaneous successful 'valve-in-valve' TAVR and debranching TEVAR using the transfemoral approach. This case demonstrated the feasibility of single-stage transfemoral TAVR and TEVAR in a high-risk patient with multicomponent disease.
Project description:Transesophageal echocardiography guides a range of structural heart disease interventions, especially in older adult and frail patients who are deemed not suitable to undergo surgical repair. Although rare, transesophageal echocardiography can be associated with esophageal trauma, including perforation. Treating physicians should be cognizant of such a complication. (Level of Difficulty: Intermediate.).
Project description:BackgroundThe axillary artery is an alternative access route for transcatheter aortic-valve implantation (TAVI) in patients who have unfavourable femoral arteries as well as comorbidities which preclude surgery. Transaxillary TAVI (TAx-TAVI), with a complete non-transfemoral approach, is a feasible and safe alternative even if complications like vascular closure device failure with bleeding occurs.Case summaryWe describe here a simplified non-transfemoral TAx-TAVI approach in a 71-year-old patient with pulmonary oedema due to severe symptomatic aortic stenosis with a prohibitively high surgical risk (Society of Thoracic Surgeons Mortality 11.9%) and extensive peripheral artery disease that rendered the femoral arteries unsuitable for access. Importantly, this strategy also allows for successful management of bleeding events, particularly those associated with vascular closure device failure, by the use of a new covered stent device. The patient was discharged on Day 6 after admission in stable conditions. In short-term follow-up (30 days), he is asymptomatic with normal left-ventricular function.DiscussionThe TAx-TAVI is a promising alternative to transfemoral TAVI approach. Patient safety, even during bleeding complications, can be guaranteed with appropriate preparation.
Project description:BackgroundValve-in-valve transcatheter aortic valve implantation (TAVI) has emerged as a competent alternative for the treatment of degenerated bioprosthetic valves after surgical aortic valve replacement, or during TAVI procedure as a bailout option. Herein, we report a rare case of a self-expandable Medtronic Evolut R valve into a failing Medtronic CoreValve, with the use of modern pre-TAVI imaging screening, suggesting the proper procedural design steps for so complicated implantations.Case summaryA frail 78-year-old woman with a degenerated Medtronic Core Valve 26 mm bioprosthesis, implanted in 2011 due to severe aortic stenosis, was referred to our hospital due to worsening dyspnoea New York Heart Association III. The screening echocardiography documented severe aortic stenosis, while the classical risk scores were in favour of repeated TAVI (EuroSCORE II 5.67%). Computed tomography measurements and three-dimensional (3D) printing model were of great help for the proper valve selection (Medtronic Evolut R 26 mm), while the use of cerebral protection device (Claret Sentinel) was considered as a necessary part of the procedure. The simultaneous use of fluoroscopy and transoesophageal echocardiogram led to optimal haemodynamic result, confirmed by the discharge echocardiogram, with a significant clinical improvement during the first month follow-up.DiscussionThe main periprocedural concerns remain valve malpositioning, coronary artery obstruction, and high remaining transvalvular gradients. The multimodality pre-TAVI imaging screening may be helpful for precise procedural design. Despite the limited use of 3D models, it is necessary to adopt such tissue-mimicking phantoms to increase the possibility of optimal procedural result.