ABSTRACT: Objective
To evaluate the role of bioimpedance-defined overhydration (BI-OH) parameters in predicting the risk of mortality and cardiovascular (CV) events in patients undergoing dialysis.Methods
We searched multiple electronic databases for studies investigating BI-OH indicators in the prediction of mortality and CV events through 23 May 2020. We assessed the effect of BI-OH indexes using unadjusted hazard ratios (HRs) and 95% confidence intervals (CIs). Sensitivity analysis was used for each outcome.Results
We included 55 studies with 104,758 patients in the meta-analysis. Extracellular water/total body water (ECW/TBW) >0.4 (HR 5.912, 95% CI: 2.016-17.342), ECW/intracellular water (ICW) for every 0.01 increase (HR 1.041, 95% CI: 1.031-1.051), and OH/ECW >15% (HR 2.722, 95% CI: 2.005-3.439) increased the risk of mortality in patients receiving dialysis. ECW/TBW >0.4 (HR 2.679, 95% CI: 1.345-5.339) and ECW/ICW per increment of 10% (HR 1.032, 95% CI: 1.017-1.047) were associated with an increased risk of CV events in patients undergoing dialysis. A 1-degree increase in phase angle was a protective factor for both mortality (HR 0.676, 95% CI: 0.474-0.879) and CV events (HR 0.736, 95% CI: 0.589-0.920).Conclusions
BI-OH parameters might be independent predictors for mortality and CV events in patients undergoing dialysis.