Unknown

Dataset Information

0

Changes in magnetic resonance imaging relaxation time on postmortem magnetic resonance imaging of formalin-fixed human normal heart tissue.


ABSTRACT:

Background

Postmortem magnetic resonance imaging (MRI) has been used to investigate the cause of death, but due to time constraints, it is not widely applied to the heart. Therefore, MRI analysis of the heart after formalin fixation was previously performed. However, the changes in MRI signal values based on the fixation time of formalin were not investigated. The objective was to investigate changes over time in the T1- and T2-values of MRI signals in normal areas of hearts removed during autopsy, hearts subsequently fixed in formalin, and heart specimens sliced for the preparation of pathological specimens.

Methods

The study subjects were 21 autopsy cases in our hospital between May 26, 2019 and February 16, 2020 whose hearts were removed and scanned by MRI. The male:female ratio was 14:7, and their ages at death ranged from 9 to 92 years (mean age 65.0 ± 19.7 years). Postmortem (PM)-MRI was conducted with a 0.3-Tesla (0.3-T) scanner containing a permanent magnet. A 4-channel QD head coil was used as the receiver coil. Scans were performed immediately after removal, post-formalin fixation, and after slicing; 7 cases were scanned at all three time points.

Results

The T1- and T2-values were calculated from the MRI signals of each sample organ at each scanning stage. Specimens were sliced from removed organs after formalin fixation, and the changes in T1- and T2-values over time were graphed to obtain an approximate curve. The median T1-values at each measurement time point tended to decrease from immediately after removal. The T2-values showed the same tendency to decrease, but this tendency was more pronounced for the T1-values.

Conclusion

MRI signal changes in images of heart specimens were investigated. Formalin fixation shortened both T1- and T2-values over time, and approximation formulae were derived to show these decreases over time. The shortening of T1- and T2-values can be understood as commensurate with the reduction in the water content (water molecules) of the formalin-fixed heart.

SUBMITTER: Ebata K 

PROVIDER: S-EPMC8459544 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC4144036 | biostudies-literature
| S-EPMC6105100 | biostudies-literature
| S-EPMC5390049 | biostudies-literature
| S-EPMC5378466 | biostudies-literature
| S-EPMC10947173 | biostudies-literature
| S-EPMC6083713 | biostudies-literature
| S-EPMC4158672 | biostudies-literature
| S-EPMC7392236 | biostudies-literature
| S-EPMC2998813 | biostudies-literature
| S-EPMC3166425 | biostudies-literature