Unknown

Dataset Information

0

LC-MS/MS Determination of 21 Non-Steroidal Anti-Inflammatory Drugs Residues in Animal Milk and Muscles.


ABSTRACT: The presented procedure combines experience from two LC-MS/MS methods previously developed by our team for NSAIDs determination in meat and milk. The novelty was a modification of sample preparation and combining LC-MS/MS method for milk and muscle. The clean-up procedure was investigated, leading to a change from SPE to dSPE with C18 bulk sorbent. Unlike most of the existing methods, chromatographic separation was achieved on a C8 chromatographic column. This method was developed and validated under European Commission Decision 2002/657/EC. Recovery for milk samples values between 86.3% to 108%, with the coefficient of variation, varied from 5.51% to 16.2%. The recovery for muscle was calculated to be between 85.0% and 109%, and the coefficient of variation was-4.73% to 16.6%. The validation results prove that the method is suitable for confirmatory purposes in milk and muscle. Of 452 samples tested in 2019 and 2020, two have been identified as non-compliant.

SUBMITTER: Pietruk M 

PROVIDER: S-EPMC8512709 | biostudies-literature |

REPOSITORIES: biostudies-literature