Unknown

Dataset Information

0

Efficacy and Safety of High-Power Short-Duration Radiofrequency Catheter Ablation of Atrial Fibrillation.


ABSTRACT: Introduction: Whereas, high-power short-duration (HPSD) radiofrequency (RF) ablation is generally used in atrial fibrillation (AF) catheter ablation (CA), its efficacy, safety, and influence on autonomic function have not been well established in a large population. This study compared HPSD-AFCA and conventional power (ConvP)-AFCA in propensity score matched-population. Methods: In 3,045 consecutive patients who underwent AFCA, this study included 1,260 patients (73.9% male, 59 ± 10 years old, 58.2% paroxysmal type) after propensity score matching: 315 in 50~60W HPSD group vs. 945 in the ConvP group. This study investigated the procedural factors, complication rate, rhythm status, and 3-month heart rate variability (HRV) between the two groups and subgroups. Results: Procedure time was considerably short in the HPSD group (135 min in HPSD vs. 181 min in ConvP, p < 0.001) compared to ConvP group, but there was no significant difference in the complication rate (2.9% in HPSD vs. 3.7% in ConvP, p = 0.477) and the 3-month HRV between the two groups. At the one-year follow-up, there was no significant difference in rhythm outcomes between the two groups (Overall, Log-rank p = 0.885; anti-arrhythmic drug free, Log-rank p = 0.673). These efficacy and safety outcomes were consistently similar irrespective of the AF type or ablation lesion set. The Cox regression analysis showed that the left atrium volume index estimated by computed tomography (HR 1.01 [1.00-1.02]), p = 0.003) and extra-pulmonary vein triggers (HR 1.59 [1.03-2.44], p = 0.036) were independently associated with one-year clinical recurrence, whereas the HPSD ablation was not (HR 1.03 [0.73-1.44], p = 0.887). Conclusion: HPSD-AFCA notably reduced the procedure time with similar rhythm outcomes, complication rate, and influence on autonomic function as ConvP-AFCA, irrespective of the AF type or ablation lesion set.

SUBMITTER: Park JW 

PROVIDER: S-EPMC8530188 | biostudies-literature | 2021

REPOSITORIES: biostudies-literature

altmetric image

Publications

Efficacy and Safety of High-Power Short-Duration Radiofrequency Catheter Ablation of Atrial Fibrillation.

Park Je-Wook JW   Yang Song-Yi SY   Kim Min M   Yu Hee Tae HT   Kim Tae-Hoon TH   Uhm Jae-Sun JS   Joung Boyoung B   Lee Moon-Hyoung MH   Pak Hui-Nam HN  

Frontiers in cardiovascular medicine 20211007


<b>Introduction:</b> Whereas, high-power short-duration (HPSD) radiofrequency (RF) ablation is generally used in atrial fibrillation (AF) catheter ablation (CA), its efficacy, safety, and influence on autonomic function have not been well established in a large population. This study compared HPSD-AFCA and conventional power (ConvP)-AFCA in propensity score matched-population. <b>Methods:</b> In 3,045 consecutive patients who underwent AFCA, this study included 1,260 patients (73.9% male, 59 ± 1  ...[more]

Similar Datasets

| S-EPMC8878944 | biostudies-literature
| S-EPMC8339091 | biostudies-literature
| S-EPMC7724222 | biostudies-literature
| S-EPMC9396586 | biostudies-literature
| S-EPMC9114024 | biostudies-literature
| S-EPMC9877396 | biostudies-literature
| S-EPMC4114331 | biostudies-literature
| S-EPMC11379757 | biostudies-literature
| S-EPMC4176074 | biostudies-other