Project description:We propose and develop a comprehensive model for estimating the refractive index (RI) response over three potential sensing zones in a multimode fiber. The model has been developed based on a combined ray optics, Gaussian beam, and wave optics analysis coupled to the consideration of the injected interrogating lightwave characteristics and validated experimentally through the realization of three sensors with different lengths of stripped cladding sections as the sensing region. The experimental results highly corroborate and validate the simulation output from the model for the three RI sensing zones. The sensors can be employed over a very wide dynamic RI range from 1.316 to over 1.608 at a wavelength of 1550 nm, with the best resolution of 2.2447 × 10-5 RI unit (RIU) obtained in Zone II for a 1-cm sensor length.
Project description:A method using single fiber reflectance spectroscopy to measure the refractive indices of transparent and turbid media over a broad wavelength range is presented and tested. For transparent liquid samples, the accuracy is within 0.2%, and the accuracy increases with increasing wavelength. For liquid turbid media, the accuracy is within 0.3% and increases with decreasing wavelength. For solid turbid samples, such as human skin, the accuracy critically depends on the optical contact between the fiber and sample surface. It is demonstrated that this technique has the potential to measure refractive indices of biological tissue in vivo.
Project description:The generation of a two-octave supercontinuum from the visible to mid-infrared (700-2800 nm) in a non-silica graded-index multimode fiber is reported. The fiber design is based on a nanostructured core comprised of two types of drawn lead-bismuth-gallate glass rods with different refractive indices. This yields an effective parabolic index profile and ten times increased nonlinearity when compared to silica fibers. Using femtosecond pulse pumping at wavelengths in both normal and anomalous dispersion regimes, a detailed study is carried out into the supercontinuum generating mechanisms and instabilities seeded by periodic self-imaging. Significantly, suitable injection conditions in the high power regime are found to result in the output beam profile showing clear signatures of beam self-cleaning from nonlinear mode mixing. Experimental observations are interpreted using spatio-temporal 3+1D numerical simulations of the generalized nonlinear Schrödinger equation, and simulated spectra are in excellent agreement with experiment over the full two-octave spectral bandwidth. Experimental comparison with the generation of supercontinuum in a silica graded-index multimode fiber shows that the enhanced nonlinear refractive index of the lead-bismuth-gallate fiber yields a spectrum with a significantly larger bandwidth. These results demonstrate a new pathway towards the generation of bright, ultrabroadband light sources in the mid-infrared.
Project description:SIGNIFICANCE:Noninvasive in vivo fast pulsatile blood flow measurement in deep tissue is important because the blood flow waveform is correlated with physiological parameters, such as blood pressure and elasticity of blood vessels. Compromised blood flow may cause diseases, such as stroke, foot ulcer, and myocardial ischemia. There is great clinical demand for a portable and cost-effective device for noninvasive pulsatile blood flow measurement. AIM:A diffuse-optics-based method, diffuse speckle pulsatile flowmetry (DSPF), was developed for fast measurement (?300??Hz) of deep tissue blood flow noninvasively. To validate its performance, both a phantom experiment and in vivo demonstration were conducted. APPROACH:Over the past two decades, single-mode fibers have been used as detection fibers in most diffuse-optics-based deep tissue blood flow measurement modalities. We used a multimode (MM) detection fiber with a core size of 200???m for diffused speckle pattern detection. A background intensity correction algorithm was implemented for speckle contrast calculation. The MM detection fiber helped to achieve a level of deep tissue blood flow measurement similar to that of conventional modalities, such as diffuse correlation spectroscopy and diffuse speckle contrast analysis, but it increases the measurement rate of blood flow to 300 Hz. RESULTS:The design and implementation of the DSPF system were introduced. The theory of the background intensity correction for the diffused speckle pattern detected by the MM fiber was explained. A flow phantom was built for validation of the performance of the DSPF system. An in vivo cuff-induced occlusion experiment was performed to demonstrate the capability of the proposed DSPF system. CONCLUSIONS:An MM detection fiber can help to achieve fast (?300??Hz) pulsatile blood flow measurement in the proposed DSPF method. The cost-effective device and the fiber-based flexible probe increase the usability of the DSPF system significantly.
Project description:Graphene oxides (GOs) have emerged as precursors offering the potential of a cost-effective and large-scale production of graphene-based materials. Despite that their intrinsic fluorescence property has already brought interest of researchers for optical applications, to date, refractive-index modulation as one of the fundamental aspects of optical properties of GOs has received less attention. Here we reported on a giant refractive-index modulation on the order of 10(-2) to 10(-1), accompanied by a fluorescence intensity change, through the two-photon reduction of GOs. These features enabled a mechanism for multimode optical recording with the fluorescence contrast and the hologram-encoded refractive-index modulation in GO-dispersed polymers for security-enhanced high-capacity information technologies. Our results show that GO-polymer composites may provide a new material platform enabling flexible micro-/nano-photonic information devices.
Project description:Multimode fibers can guide thousands of modes capable of delivering spatial information. Unfortunately, mode dispersion and coupling have so far prevented their use in endoscopic applications. To address this long-lasting challenge, we present a robust scanning fluorescence endoscope. A spatial light modulator shapes the input excitation wavefront to focus light on the distal tip of the fiber and to rapidly scan the focus over the region of interest. A detector array collects the fluorescence emission propagated back from the sample to the proximal tip of the fiber. We demonstrate that proper selection of the multimode fiber is critical for a robust calibration and for high signal-to-background ratio performance. We compare different types of multimode fibers and experimentally show that a focus created through a graded-index fiber can withstand a few millimeters of fiber distal tip translation. The resulting scanning endoscopic microscope images fluorescent samples over a field of view of 80µm with a resolution of 2µm.
Project description:High-resolution compressive imaging via a flexible multimode fiber is demonstrated using a swept-laser source and wavelength dependent speckle illumination. An in-house built swept-source allowing for independent control of bandwidth and scanning range is used to explore and demonstrate a mechanically scan-free approach for high-resolution imaging through an ultrathin and flexible fiber probe. The computational image reconstruction is shown by utilizing a narrow sweeping bandwidth of [Formula: see text] nm while acquisition time is decreased by 95% compared to conventional raster scanning endoscopy. Demonstrated narrow-band illumination in the visible spectrum is vital for the detection of fluorescence biomarkers in neuroimaging applications. The proposed approach yields device simplicity and flexibility for minimally invasive endoscopy.
Project description:We developed a microscopy technique that can measure the local refractive index without sampling the optical phase delay of the electromagnetic radiation. To do this, we designed and experimentally demonstrated a setup with two colocalized Brillouin scattering interactions that couple to a common acoustic phonon axis; in this scenario, the ratio of Brillouin frequency shifts depends on the refractive index, but not on any other mechanical and/or optical properties of the sample. Integrating the spectral measurement within a confocal microscope, the refractive index is mapped at micron-scale three-dimensional resolution. As the refractive index is probed in epidetection and without assumptions on the geometrical dimensions of the sample, this method may prove useful to characterize biological cells and tissues.
Project description:A photonic crystal fiber (PCF) structure with a ring-core and 5 well-ordered semiellipse air-holes has been creatively proposed. Through a comparison between the structures with a high refractive index (RI) ring-core and the structure without, it conclude that a PCF with a high RI ring-core can work better. Schott SF57 was elected as the substrate material of ring-core. This paper compares the effects of long-axis and short-axis changes on the PCF and selects the optimal solution. Especially TE0,1 mode's dispersion is maintained between 0 and 3 ps / (nm · km) ranging from 1.45 ?m to 1.65 ?m. This property can be used to generate a supercontinuum with 200 ?m long zero dispersion wavelength (ZDM). In addition, ?neff reaches up to 10-3, which enables the near -degeneracy of the eigenmodes to be almost neglected. The proposed PCF structure will have great application value in the field of optical communications.