Automatic Continuous Control of Cuff Pressure and Subglottic Secretion Suction Used Together to Prevent Pneumonia in Ventilated Patients-A Retrospective and Prospective Cohort Study.
Ontology highlight
ABSTRACT: The ventilator bundle consists of multiple methods to reduce ventilator-associated pneumonia (VAP) rates in Intensive Care Units (ICU). The aim of the study was to evaluate how the continuous automatic pressure control in tapered cuffs of endotracheal/tracheostomy tubes applied along with continuous automatic subglottic secretion suction affect the incidence of VAP. In the prospective cohort (n = 198), the standard VAP bundle was modified by continuous automatic pressure control in taper-shaped cuff of endotracheal/tracheostomy tubes and subglottic secretion suction. VAP incidence, time to VAP onset, invasive mechanical ventilation days/free days, length of ICU stay, ICU mortality, and multidrug-resistant bacteria were assessed and compared to the retrospective cohort (n = 173) with the standard bundle (intermittent cuff pressure of standard cuff, lack of subglottic secretion suction). A smaller incidence of VAP (9.6% vs. 19.1%) and early onset VAP (1.5% vs. 8.1%) was found in the prospective compared to the retrospective cohort (p < 0.01). Patients in the prospective cohort were less likely to develop VAP (RR = 0.50; 95% CI: 0.29 to 0.85) and early-onset VAP (RR = 0.19; 95% CI: 0.05 to 0.64) and had longer time to onset VAP (median 9 vs. 5 days; p = 0.03). There was no significant difference (p > 0.05) between both cohorts in terms of invasive mechanical ventilation days/free days, length of ICU stay, ICU mortality and multidrug-resistant bacteria. Modification of the bundle for prevention of VAP can reduce early-onset VAP and total incidence of VAP and delay the time of VAP occurrence.
SUBMITTER: Tomaszek L
PROVIDER: S-EPMC8584498 | biostudies-literature |
REPOSITORIES: biostudies-literature
ACCESS DATA