Project description:A 63-year-old man with cirrhosis, hepatocellular carcinoma, and coagulopathy was diagnosed with a sinus venosus atrial septal defect (ASD) and partial anomalous pulmonary venous return (PAPVR) of the right upper pulmonary vein (RUPV). Transcatheter repair by positioning a stent graft in the superior vena cava was planned. Based on three-dimensional (3D) reconstruction of gated cardiac CTA, a 28 mm × 7 cm Endurant II® aortic extension stent graft (Medtronic, MN) was chosen. A 3D model printed from the CTA was used to simulate device deployment, demonstrating successful exclusion of the sinus venosus ASD with return of the RUPV to the left atrium (LA). Post simulation, the 3D model was used for informed consent. The patient was then taken to the hybrid operating room. On-table cone beam CT was performed and registered with the CTA images. This enabled overlay of 3D regions of interest to live 2D fluoroscopy. The stent graft was then deployed using 3D regions of interest for guidance. Hemodynamics and angiography demonstrated successful exclusion of the sinus venosus ASD and unobstructed return of RUPV to the LA. This is the first report of comprehensive use of contemporary imaging for planning, simulation, patient consent, and procedural guidance for patient-centered complex structural intervention in repair of sinus venosus ASD with PAPVR. We propose this as a process model for continued innovation in structural interventions.
Project description:Background:Septal malalignment is related to erosion and device embolization in transcatheter closure of atrial septal defect (ASD), but limited information is available. Objectives:This study aimed to assess clinical significance of septal malalignment and to determine appropriate evaluation of ASD diameter, including the selection of device size. Methods:Four hundred and seventeen patients with ASD who underwent transcatheter closure were enrolled. Septal malalignment was defined as separation between the septum primum and the septum secundum on transesophageal echocardiography. Results:One hundred and eighty-four patients had septal malalignment. The frequency of septal malalignment increased with age reaching around 50% in adult patients. Septal malalignment was related to aortic rim deficiency. The distance of separation between the septum primum and the septum secundum was 5?±?2?mm (range, 1-11?mm). In patients with septal malalignment, the ASD diameter measured at the septum primum was 19?±?6?mm, while the ASD diameter measured at the septum secundum was 16?±?6?mm. There was a difference of 4?±?2?mm (range, 0-8?mm) between the ASD diameter measured at the septum primum and that measured at the septum secundum. For transcatheter closure, the Amplatzer Septal Occluder device size 2-3?mm larger and the Occlutech Figulla Flex II device size 4-7?mm larger than the ASD diameter measured at the septum primum were frequently used. During the study period, erosion or device embolization did not occur in all of the patients. Conclusions:Septal malalignment is highly prevalent in adult patients with aortic rim deficiency. The measurement of ASD diameter at the septum primum can be valuable for the selection of device size in patients with septal malalignment.
Project description:Background Current guidelines recommend at least 6 months of antithrombotic therapy and antibiotic prophylaxis after septal-occluding device deployment in transcatheter closure of atrial septal defect. It has been estimated that it takes ≈6 months for complete neo-endothelialization; however, neo-endothelialization has not previously been assessed in vivo in humans. Methods and Results The neointimal coverage of septal occluder devices was evaluated 6 months after implantation in 15 patients by angioscopy from the right atrium. Each occluder surface was divided into 9 areas; the levels of endothelialization in each area were semiquantitatively assessed by 4-point grades. Device neo-endothelialization was sufficient in two thirds of patients, but insufficient in one third. In the comparison between patients with sufficiently endothelialized devices of average grade score ≥2 (good endothelialization group, n=10) and those with poorly endothelialized devices of average grade score <2 (poor endothelialization group, n=5), those in the poor endothelialization group had larger devices deployed (27.0 mm [25.0-31.5 mm] versus 17.0 mm [15.6-22.5 mm], respectively) and progressive right heart dilatation. The endothelialization was poorer around the central areas. Moreover, the prevalence of thrombus formation on the devices was higher in the poorly endothelialized areas than in the sufficiently endothelialized areas (Grade 0, 94.1%; Grade 1, 63.2%; Grade 2, 0%; Grade 3, 1.6%). Conclusions Neo-endothelialization on the closure devices varied 6 months after implantation. Notably, poor endothelialization and thrombus attachment were observed around the central areas and on the larger devices.
Project description:A 92-year-old man was referred to our hospital with decompensated heart failure. He was treated with diuretics and inotropic agents, but the clinical response was unsatisfactory. Echocardiography incidentally revealed an atrial septal defect (ASD) with a significant left-to-right shunt and pulmonary-to-systemic-blood-flow ratio of 2.36. Because the ASD was considered to be the primary cause of his treatment-resistant heart failure, the patient underwent transcatheter ASD closure. Shortly after shunt closure, his hemodynamics significantly improved, and he was discharged nine days later. This is an extremely rare case of a nonagenarian who showed an excellent clinical course after transcatheter ASD closure.
Project description:Cor triatriatum dexter is an extremely rare congenital heart defect and cause of hypoxia in adults. We describe a case of cor triatriatum dexter discovered incidentally due to an iatrogenic atrial septal defect. The cor triatriatum dexter resolved with balloon dilation - a novel technique to manage this rare clinical condition. <Learning objective: Management of cor triatriatum dexter, an exceptionally rare diagnosis, has often been thought to be surgical. However, percutaneous intervention may be considered in select clinical situations.>.
Project description:Atrial septal defect (ASD) is a common congenital defect that leads to various hemodynamic complications if untreated. Transcatheter closure (TCC) of isolated secundum ASD is the preferred treatment. Herein we describe a unique malaligned ASD secondary to a membranous chord. With balloon sizing and intracardiac echocardiography (ICE), TCC was successfully pursued. (Level of Difficulty: Beginner.).
Project description:Atrial septal defect (ASD) and patent ductus arteriosus (PDA) are both common congenital heart diseases, but the combination of these two cardiac defects is extremely rare, and the therapeutic strategy is controversial. We treated an adult patient with combined ASD and PDA, and safely attained a successful outcome with two-stage transcatheter closure, which is PDA closure preceding ASD closure, to prevent serious complications. Transcatheter closure of one of the defects is now widely accepted as an alternative to surgical closure. In addition, adults with both ASD and PDA are better suited for transcatheter closure than surgical closure. One of the reasons is the difficulty to ligate the ductus arteriosus of an adult patient due to its friability and calcification. Meanwhile, simultaneous combined transcatheter closure of ASD and PDA can result in serious complications, such as thrombocytopenia and haemolysis, whose mechanism is considered to be the destruction of platelets and red blood cells by the residual shunt through implanted devices. Additionally, antiplatelet therapy that prevents device-related thrombus formation after ASD closure can possibly exacerbate thrombocytopenia and haemolysis. Therefore, the staged strategy is reasonable from the perspectives of antiplatelet therapy and haemodynamic changes.