Signal intensity ratio of draining vein on silent MR angiography as an indicator of high-flow arteriovenous shunt in brain arteriovenous malformation.


ABSTRACT:

Objectives

To evaluate whether the signal intensity ratio (rSI) of the draining vein on silent MR angiography is correlated with arteriovenous (A-V) transit time on digital subtraction angiography (DSA), thereby identifying high-flow A-V shunt in brain arteriovenous malformation (BAVM), and to analyze whether the rSI and the characteristic of draining veins on silent MRA are associated with hemorrhage presentation.

Methods

Eighty-one draining veins of 46 participants with BAVM (mean age 33.2 ± 16.9 years) who underwent silent MRA and DSA were evaluated retrospectively. The correlation between the rSI of the draining vein on silent MRA and A-V transit time on DSA was examined. The AUC-ROC was obtained to evaluate the performance of the rSI in determining the presence of high-flow A-V shunt. The characteristics of draining veins with the maximum rSI (rSImax) were further compared between the hemorrhagic and non-hemorrhagic untreated BAVM.

Results

The rSI of each draining vein on silent MRA was significantly correlated with A-V transit time from DSA (r = -0.81, p < .001). The AUC-ROC was 0.89 for using the rSI to determine the presence of high-flow A-V shunt. A cut-off rSI value of 1.09 yielded a sensitivity of 82.4% and a specificity of 82.8%. The draining vein with rSImax and no ectasia was significantly more observed in the hemorrhagic group (p = 0.045).

Conclusions

The rSI of the draining vein on silent MRA is significantly correlated with A-V transit time on DSA, and it can be used as an indicator of high-flow A-V shunt in BAVM.

Key points

• The signal intensity ratio (rSI) of the draining vein on silent MRA significantly correlated with arteriovenous (A-V) transit time of brain arteriovenous malformation (BAVM) on digital subtraction angiography (DSA). • The area under the receiver operating characteristic curve (AUC) was 0.89 for using the rSI of draining veins to determine high-flow A-V shunt. • Draining veins with maximum rSI and no ectasia were significantly more observed in the hemorrhagic group of BAVM (p = 0.045).

SUBMITTER: Wu CX 

PROVIDER: S-EPMC8589750 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC9260105 | biostudies-literature
| S-EPMC3335931 | biostudies-literature
| S-EPMC8853956 | biostudies-literature
| S-EPMC8142145 | biostudies-literature
| S-EPMC7390970 | biostudies-literature
| S-EPMC8498570 | biostudies-literature
| S-EPMC3480811 | biostudies-other
| S-EPMC7655400 | biostudies-literature
2024-05-30 | GSE245171 | GEO
| S-EPMC6491094 | biostudies-literature