Unknown

Dataset Information

0

Effects of Rebamipide on Differences in Power and Axis of Corneal Astigmatism Between Two Intra-patient Keratometric Measurements in Dry Eyes.


ABSTRACT:

Introduction

This study investigated the effect of rebamipide on discrepancies in the power and axis of astigmatism between two intra-patient keratometric measurements in patients with dry eyes.

Methods

Fifty-eight dry eyes (with a short tear breakup time [TBUT] of less than 5 s) were analyzed. Patients with dry eye were treated with 2% rebamipide ophthalmic suspension (group R) or Mytear® artificial tear ophthalmic solution (group M) for 4 weeks. TBUT and corneal higher-order aberrations (HOAs) were evaluated at baseline and 4 weeks after treatment. Astigmatism power and axis were measured twice during both evaluations, at 5-min intervals. Baseline and post-treatment measurements were compared. Changes in TBUT and HOAs, and intra-patient discrepancies in astigmatism power and axis measurements were evaluated.

Results

HOAs showed significant positive correlations with intra-patient differences in astigmatism power and axis (P < 0.001). At the 4-week post-treatment follow-up, TBUT increased, and HOAs and astigmatism power and axis discrepancies decreased in a significant number of patients in group R (P < 0.001). In group M, only differences in astigmatism power decreased in a significant number of cases (P = 0.005). The degree of change in the intra-patient difference in astigmatism power between the two post-treatment keratometric measurements was significantly greater in group R than in group M (P < 0.001). In group R, baseline HOAs exhibited a significant positive correlation with changes in HOAs and intra-patient differences in astigmatism power (both P < 0.001). In group M, baseline HOAs were only significantly correlated with changes in intra-patient differences in astigmatism power (P = 0.030).

Conclusion

In dry eyes with short TBUTs, rebamipide significantly improved the corneal surface condition and significantly reduced intra-patient discrepancies in astigmatism power and axis measurements. Rebamipide may improve the accuracy of intraocular lens (IOL) power calculations in dry eyes, particularly when toric IOLs are implanted.

SUBMITTER: Teshigawara T 

PROVIDER: S-EPMC8589897 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC6219330 | biostudies-literature
| S-EPMC3904857 | biostudies-literature
| S-EPMC7685436 | biostudies-literature
| S-EPMC7749028 | biostudies-literature
| S-EPMC6719011 | biostudies-literature
| S-EPMC7569024 | biostudies-literature
| S-EPMC6553727 | biostudies-literature
| S-EPMC4283956 | biostudies-literature
| S-EPMC6051070 | biostudies-literature
| S-EPMC4658226 | biostudies-literature