Project description:We investigated the infectivity of 128 severe acute respiratory disease coronavirus 2-associated deaths and evaluated predictive values of standard diagnostic procedures. Maintained infectivity (20%) did not correlate with viral RNA loads but correlated well with anti-S antibody levels. Sensitivity >90% for antigen-detecting rapid diagnostic tests supports their usefulness for assessment.
Project description:The SARS-CoV-2 antigen-detecting rapid diagnostic test (Ag-RDTs) is an easy-to-use diagnostic tool to identify the contagious individuals and reduce the new infections. However, to be effective, Ag-RDTs require the detection of distinct variants of concern (VOC) with high analytical sensitivity. Here, we found that the VOC diverge at the nucleocapsid protein used by four commercial Ag-RDTs for the viral detection. Relative to the original D614G variant, there was a 10-fold loss of detection for the Delta and Alpha variants in certain Ag-RDTs, a reduction above the threshold required to isolate the viable virus. However, Beta and Omicron variants did not lose the detection capacity. As the new VOC arise, successful contact tracing requires continuous monitoring of Ag-RDTs performance.
Project description:PurposeOmicron is rapidly spreading as a new SARS-CoV-2 variant of concern (VOC). The question whether this new variant has an impact on SARS-CoV-2 rapid antigen test (RAT) performance is of utmost importance. To obtain an initial estimate regarding differences of RATs in detecting omicron and delta, seven commonly used SARS-CoV-2 RATs from different manufacturers were analysed using cell culture supernatants and clinical specimens.MethodsFor this purpose, cell culture-expanded omicron and delta preparations were serially diluted in Dulbecco's modified Eagle's Medium (DMEM) and the Limit of Detection (LoD) for both VOCs was determined. Additionally, clinical specimens stored in viral transport media or saline (n = 51) were investigated to complement in vitro results with cell culture supernatants. Ct values and RNA concentrations were determined via quantitative reverse transcription polymerase chain reaction (RT-qPCR).ResultsThe in vitro determination of the LoD showed no obvious differences in detection of omicron and delta for the RATs examined. The LoD in this study was at a dilution level of 1:1,000 (corresponding to 3.0-5.6 × 106 RNA copies/mL) for tests I-V and at a dilution level of 1:100 (corresponding to 3.7-4.9 × 107 RNA copies/mL) for tests VI and VII. Based on clinical specimens, no obvious differences were observed between RAT positivity rates when comparing omicron to delta in this study setting. Overall positivity rates varied between manufacturers with 30-81% for omicron and 42-71% for delta. Test VII was only conducted in vitro with cell culture supernatants for feasibility reasons. In the range of Ct < 23, positivity rates were 50-100% for omicron and 67-93% for delta.ConclusionIn this study, RATs from various manufacturers were investigated, which displayed no obvious differences in terms of analytical LoD in vitro and RAT positivity rates based on clinical samples comparing the VOCs omicron and delta. However, differences between tests produced by various manufacturers were detected. In terms of clinical samples, a focus of this study was on specimens with high virus concentrations. Further systematic, clinical and laboratory studies utilizing large datasets are urgently needed to confirm reliable performance in terms of sensitivity and specificity for all individual RATs and SARS-CoV-2 variants.
Project description:The objective of this study was to develop a scalable approach for direct comparison of the analytical sensitivities of commercially available SARS-CoV-2 antigen point-of-care tests (AgPOCTs) to rapidly identify poor-performing products. We present a methodology for quick assessment of the sensitivity of SARS-CoV-2 AgPOCTs suitable for quality evaluation of many different products. We established reference samples with high, medium, and low SARS-CoV-2 viral loads along with a SARS-CoV-2 negative control sample. Test samples were used to semi-quantitatively assess the analytical sensitivities of 32 different commercial AgPOCTs in a head-to-head comparison. Among 32 SARS-CoV-2 AgPOCTs tested, we observe sensitivity differences across a broad range of viral loads (9.8 × 108 to 1.8 × 105 SARS-CoV-2 genome copies per ml). 23 AgPOCTs detected the Ct25 test sample (1.6 × 106 copies/ml), while only five tests detected the Ct28 test sample (1.8 × 105 copies/ml). In the low-range of analytical sensitivity, we found three saliva spit tests only delivering positive results for the Ct21 sample (2.7 × 107 copies/ml). Comparison with published data supports our AgPOCT ranking. Importantly, we identified an AgPOCT widely offered, which did not reliably recognize the sample with the highest viral load (Ct16 test sample with 9.8 × 108 copies/ml) leading to serious doubts about its usefulness in SARS-CoV-2 diagnostics. The results show that the rapid sensitivity assessment procedure presented here provides useful estimations on the analytical sensitivities of 32 AgPOCTs and identified a widely-spread AgPOCT with concerningly low sensitivity.
Project description:Responding to the fast-spreading SARS-CoV-2 Omicron variant, to improve screening efficiency, rapid antigen tests (RATs) were first added as a supplementary detection method in China in mid-March, 2022. What and how big a role RATs should play need to be supported by clinical data. Here, RAT performance and relevant factors in comparison with nucleic acid amplification tests (NAATs) were assessed in Omicron-infected inpatients. From the NAAT results, nasopharyngeal swabs (NPs) performed better than oropharyngeal swabs (OPs). RATs tested on NAAT positive NPs performed better than those with OP-positive samples. The RAT positivity rate was strongly associated with high levels of N and OFR1ab genes, especially in NPs where patients also had significantly longer hospital stays and shorter days from symptom onset to RAT testing. Self-performed RATs had a detection accuracy that was comparable to professionally performed RATs when the subjects were well guided. The antigen negative rate of the studied patients was 100% at discharge. These findings suggest that, in addition to a supplementary detection role, RATs can be an important strategy for evaluating the disease progression of Omicron-infected inpatients. This study provides important clinical data to support better rules regarding RATs under China's COVID-19 prevention and control policy.
Project description:The emergence of the B.1.617.2 (Delta) variant of the severe acute syndrome coronavirus (SARS-CoV-2) that emerged in 2019 (COVID-19), resulted in a surge of cases in India and has expanded and been detected across the world, including in the United States. The B.1.617.2 (Delta) variant has been seen to be twice more transmissible coupled with potential increases in disease severity and immune escape. As a result, case numbers and hospitalisations are once again on the rise in the USA. On 16 July 2021, the Centers for Disease Control and Prevention (CDC) reported a 7-day average 69.3% increase in new cases and a 35% increase in hospitalisations. Although the gold standard for SARS-CoV-2 variants identification remains genomic sequencing, this approach is not accessible to many clinical laboratories. The main goal of this study was to validate and implement the detection of the B.1.617.2 (Delta) variant utilising an open reverse transcription polymerase chain reaction (RT-PCR) platform by explicitly detecting the S-gene target failure (SGTF) corresponding to the deletion of two amino acids (ΔE156/ΔF157) characteristic of B.1.617.2 (Delta) variant. This approach was conceived as a rapid screening of B.1.617.2 (Delta) variant in conjunction with CDC's recommended N1 (nucleocapsid gene), N2, and RP (human RNase P) genes, as a pre-screening tool prior to viral genomic sequencing. We assessed 4,937 samples from 5 July to 5 September 2021. We identified the B.1.617.2 (Delta) variant in 435 of 495 positive samples (87.8%); the additional positive samples (7 samples, 1.4%) were found to belong to the B.1.1.7 (Alpha, UK) lineage and the remaining 53 samples (10.7%) were reported as 'other' lineages. Whole genome sequencing of 46 randomly selected samples validated the strains identified as positive and negative for the B.1.617.2 (Delta) variant and confirmed the S gene deletion in addition to B.1.617.2 characteristic mutations including L452R, T478K, P681R and D950N located in the spike protein. This modality has been used as routine testing at the Riverside University System Health (RUHS) Medical Center as a method for detection of B.1.617.2 (Delta) to pre-screen samples before genome sequencing. The assay can be easily implemented in clinical laboratories, most notably those with limited economic resources and access to genomic platforms.
Project description:The search for effective methods to detect patients who excrete a viable virus is one of the urgent tasks of modern biomedicine. In the present study, we examined the diagnostic value of two antigen tests, BIOCREDIT COVID-19 Ag (RapiGEN Inc., Anyang, Korea) and SGTI-flex COVID-19 Ag (Sugentech Inc., Cheongju, Korea), for their diagnostic value in identifying patients who excrete viable SARS-CoV-2. As part of the study, we examined samples from 106 patients who had just been admitted to the hospital and who had undergone quantitative RT-PCR and assessment of viability of SARS-CoV-2 using cell culture. Assessment of the tests' value for detecting samples containing viable virus showed high sensitivity for both tests. Sensitivity was 78.6% (95% CI, from 49.2% to 95.3%) for SGTI-flex COVID-19 Ag and 100% (95% CI, from 76.8% to 100%) for Biocredit COVID-19 Ag. The specificity of rapid tests was significantly higher than that of RT-PCR and was 66.3% (95% CI, from 55.7% to 75.8%) and 67.4% (95% CI, from 56.8% to 76.8%) for SGTI-flex COVID-19 Ag and Biocredit COVID-19 Ag versus 30.4% (95% CI, from 21.3% to 40.9%) obtained for PCR. Thus, for tasks of identifying viable SARS-CoV-2 during screening of conditionally healthy people, as well as monitoring those quarantined, rapid tests show significantly better results.
Project description:The clinical performance of two rapid antigen tests for the diagnosis of Severe Acute Respiratory Coronavirus (SARS-CoV-2) were regionally evaluated in East African populations. Swabs were collected from 1,432 individuals from five Partner States of the East African Community (Tanzania, Uganda, Burundi, Rwanda and South Sudan). The two rapid antigen tests (Bionote NowCheck COVID-19 Ag and SD Biosensor STANDARD Q COVID-19 Ag) were evaluated against the detection of SARS-CoV-2 RNA by the Reverse Transcription PCR (RT-PCR) gold standard. Of the concordant results with both RT-PCR and rapid antigen test data (862 for Bionote and 852 for SD Biosensor), overall clinical sensitivity was 60% and 50% for the Bionote NowCheck and the SD Biosensor STANDARD Q, respectively. Stratification by viral load, including samples with RT-PCR cycle thresholds (Ct) of <25, improved sensitivity to 90% for both rapid diagnostic tests (RDTs). Overall specificity was good at 99% for both antigen tests. Taken together, the clinical performance of both Ag-RDTs in real world settings within the East African target population was lower than has been reported elsewhere and below the acceptable levels for sensitivity of >80%, as defined by the WHO. Therefore, the rapid antigen test alone should not be used for diagnosis but could be used as part of an algorithm to identify potentially infectious individuals with high viral load. IMPORTANCE Accurate diagnostic tests are essential to both support the management and containment of outbreaks, as well as inform appropriate patient care. In the case of the SARS-CoV-2 pandemic, antigen Rapid Diagnostic Tests (Ag-RDTs) played a major role in this function, enabling widespread testing by untrained individuals, both at home and within health facilities. In East Africa, a number of SARS-CoV-2 Ag-RDTs are available; however, there remains little information on their true test performance within the region, in the hands of the health workers routinely carrying out SARS-CoV-2 diagnostics. This study contributes test performance data for two commonly used SARS-CoV-2 Ag-RDTs in East Africa, which will help inform the use of these RDTs within the region.
Project description:ImportanceVariants of SARS-CoV-2 have sequence variations in the viral genome that may alter the accuracy of rapid diagnostic tests.ObjectiveTo assess the analytical and clinical accuracy of 2 rapid diagnostic tests for detecting SARS-CoV-2 during 3 phases of variants.Design, setting, and participantsThis diagnostic study included participants aged 18 years or older who reported onset of COVID-19-like symptoms within the prior 5 days and were tested at multiple COVID-19 testing locations in King County, Washington, from February 17, 2021, to January 11, 2022, during 3 distinct phases of SARS-CoV-2 infection (pre-Delta, Delta, and Omicron).InterventionsTwo anterior nasal swab specimens were collected from each participant-1 for onsite testing by the SCoV-2 Ag Detect Rapid Self-Test and 1 for reverse transcriptase-polymerase chain reaction (RT-PCR) testing.Main outcomes and measuresThe analytical limit of detection of the 2 rapid diagnostic tests (SCoV-2 Ag Detect Rapid Self-Test and BinaxNOW COVID-19 Ag Card) was assessed using Omicron (B.1.1.529/BA.1), Delta (B.1.617.2), and a wild-type (USA-WA1/2020) variant. Diagnostic sensitivity and specificity of clinical testing for the rapid antigen tests were compared with that of RT-PCR testing.ResultsA total of 802 participants were enrolled (mean [SD] age, 37.3 [13.3] years; 467 [58.2%] female), 424 (52.9%) of whom had not received COVID-19 vaccination and presented a median of 2 days (IQR, 1-3 days) from symptom onset. Overall, no significant differences were found in the analytical limit of detection or clinical diagnostic accuracy of rapid antigen testing across SARS-CoV-2 variants. The estimated limit of detection for both rapid nucleocapsid antigen tests was at or below a 50% tissue culture infectious dose of 62.5, and the positive percent agreement of the SCoV-2 Ag Detect Rapid Self-Test ranged from 81.2% (95% CI, 69.5%-89.9%) to 90.7% (95% CI, 77.9%-97.4%) across the 3 phases of variants. The diagnostic sensitivity increased for nasal swabs with a lower cycle threshold by RT-PCR, which correlates with a higher viral load.Conclusions and relevanceIn this diagnostic study, analytical and clinical performance data demonstrated accuracy of 2 rapid antigen tests among adults with COVID-19 symptoms across 3 phases of SARS-CoV-2 variants. The findings suggest that home-based rapid antigen testing programs may be an important intervention to reduce global SARS-CoV-2 transmission.
Project description:We analysed 9,030 variant-specific RT-PCR tests performed on SARS-CoV-2-positive samples collected in France between 31 May and 21 June 2021. This analysis revealed rapid growth of the Delta variant in three of the 13 metropolitan French regions and estimated a +79% (95% confidence interval: 52-110%) transmission advantage compared with the Alpha variant. The next weeks will prove decisive and the magnitude of the estimated transmission advantages of the Delta variant could represent a major challenge for public health authorities.