Ontology highlight
ABSTRACT: Background
Actual cardiopulmonary resuscitation (CPR) guidelines recommend point-of-care ultrasound (POCUS); however, data on POCUS during CPR are sparse and conflicting. This randomized trial investigated the effects of POCUS during CPR on team performance and diagnostic accuracy.Methods
Intensive Care and Emergency Medicine residents performed CPR with or without available POCUS in simulated cardiac arrests. The primary endpoint was hands-on time. Data analysis was performed using video recordings.Results
Hands-on time was 89% (87-91) in the POCUS and 92% (89-94) in the control group (difference 3, 95% CI for difference 2-4, p < 0.001). POCUS teams had delayed defibrillator attachments (33 vs. 26 sec, p = 0.017) and first rhythm analysis (74 vs. 52 sec, p = 0.001). Available POCUS was used in 71%. Of the POCUS teams, 3 stated a POCUS-derived diagnosis, with 49 being correct and 42 followed by a correct treatment decision. Four teams made a wrong diagnosis and two made an inappropriate treatment decision.Conclusions
POCUS during CPR resulted in lower hands-on times and delayed rhythm analysis. Correct POCUS diagnoses occurred in 52%, correct treatment decisions in 44%, and inappropriate treatment decisions in 2%. Training on POCUS during CPR should focus on diagnostic accuracy and maintenance of high-quality CPR.
SUBMITTER: Zollner K
PROVIDER: S-EPMC8625670 | biostudies-literature |
REPOSITORIES: biostudies-literature