The Wavelia Microwave Breast Imaging system-tumour discriminating features and their clinical usefulness.


ABSTRACT:

Objective

The Wavelia Microwave Breast Imaging (MBI) system, based on non-ionising imaging technology, has demonstrated exciting potential in the detection and localisation of breast pathology in symptomatic patients. In this study, the ability of the system to accurately estimate the size and likelihood of malignancy of breast lesions is detailed, and its clinical usefulness determined.

Methods

Institutional review board and Health Products Regulatory Authority (HPRA) approval were obtained. Patients were recruited from the symptomatic unit to three groups; breast cancer (Group-1), unaspirated cysts (Group-2) and biopsied benign lesions (Group-3). MBI, radiological and histopathological findings were reviewed. MBI size estimations were compared with the sizes determined by conventional imaging and histopathology. A Quadratic Discriminant Analysis (QDA) classifier was trained in a 3D feature space to discriminate malignant from benign lesions. An independent review was performed by two independent breast radiologists.

Results

24 patients (11 Group-1, 8 Group-2 and 5 Group-3) underwent MBI. The Wavelia system was more accurate than conventional imaging in size estimation of breast cancers. The QDA accurately separated benign from malignant breast lesions in 88.5% of cases. The addition of MBI and the Wavelia malignancy risk calculation was deemed useful by the two radiologists in 70.6% of cases.

Conclusion

The results from this MBI investigation demonstrate the potential of this novel system in estimating size and malignancy risk of breast lesions. This system holds significant promise as a potential non-invasive, comfortable, and harmless adjunct for breast cancer diagnosis. Further larger studies are under preparation to validate the findings of this study.

Advances in knowledge

This study details the potential of the Wavelia MBI system in delineating size and malignancy risk of benign and malignant breast lesions in a symptomatic cohort. The usefulness of the Wavelia system is assessed in the clinical setting.

SUBMITTER: Moloney BM 

PROVIDER: S-EPMC8631021 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC10456176 | biostudies-literature
| S-EPMC6163546 | biostudies-other
| S-EPMC6164632 | biostudies-other
| S-EPMC3365915 | biostudies-other
| S-EPMC3598775 | biostudies-literature
| S-EPMC9230849 | biostudies-literature
| S-EPMC6315968 | biostudies-other
| S-EPMC6244182 | biostudies-literature
| S-EPMC4156007 | biostudies-literature
| S-EPMC9167165 | biostudies-literature