Prevention of coronary obstruction in patients at risk undergoing transcatheter aortic valve implantation: the Hamburg BASILICA experience.


ABSTRACT:

Objectives

This study aimed to assess the clinical outcome of the bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary obstruction (BASILICA) technique in a single-center patient cohort considered at high or prohibitive risk of transcatheter aortic valve implantation (TAVI)-induced coronary obstruction.

Methods

Between October 2019 and January 2021, a total of 15 consecutive patients (age 81.0 [78.1, 84.4] years; 53.3% female; EuroSCORE II 10.6 [6.3, 14.8] %) underwent BASILICA procedure prior to TAVI at our institution. Indications for TAVI were degeneration of stented (n = 12, 80.0%) or stentless (n = 1, 6.7%) bioprosthetic aortic valves, or calcific stenosis of native aortic valves (n = 2, 13.3%), respectively. Individual risk of TAVI-induced coronary obstruction was assessed by pre-procedural computed tomography analysis. Procedural and 30-day outcomes were documented in accordance with Valve Academic Research Consortium (VARC)-2 criteria.

Results

BASILICA was attempted for single left coronary cusp in 12 patients (80.0%), for single right coronary cusp in 2 patients (13.3%), and for both cusps in 1 patient (6.7%), respectively. The procedure was feasible in 13 patients (86.7%) resulting in effective prevention of coronary obstruction, whilst TAVI was performed without prior successful bioprosthetic leaflet laceration in two patients (13.3%). In one of these patients (6.7%), additional chimney stenting immediately after TAVI was performed. No all-cause deaths or strokes were documented after 30 days.

Conclusion

The BASILICA technique appears to be a feasible, safe and effective concept to avoid iatrogenic coronary artery obstruction during TAVI in both native and bioprosthetic valves of patients at high or prohibitive risk. ClinicalTrials.gov Identifier: NCT04227002 (Hamburg AoRtic Valve cOhoRt).

SUBMITTER: Westermann D 

PROVIDER: S-EPMC8639537 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC6724191 | biostudies-literature
| S-EPMC9086549 | biostudies-literature
| S-EPMC10229261 | biostudies-literature
| S-EPMC5371631 | biostudies-literature
| S-EPMC9821207 | biostudies-literature
| S-EPMC6805808 | biostudies-other
| S-EPMC7033916 | biostudies-literature
| S-EPMC11308060 | biostudies-literature
| S-EPMC7894507 | biostudies-literature