ABSTRACT: Background
Annuloplasty failure caused by ring dehiscence can lead to trans-ring and para-ring mitral regurgitation (MR). Transcatheter treatments are available for patients at prohibitive risk of surgery. In patients unsuitable for edge-to-edge repair, valve-in-ring (ViR) transcatheter mitral valve (MV) implantation has been described to treat trans-ring or para-ring jets but not both concurrently.Case summary
A 78-year-old male presented with severe MR due to dehiscence of a 34 mm Edwards Physio II mitral annuloplasty ring. Transoesophageal echocardiography showed two jets of regurgitation; trans-ring and para-ring. Repair was successfully undertaken with a ViR procedure (29 mm S3 Edwards Lifesciences).Discussion
Patients with failure of MV annuloplasty with trans-ring and para-ring regurgitation can be safely and effectively treated by ViR transcatheter MV implantation.
SUBMITTER: Sharma H
PROVIDER: S-EPMC8669564 | biostudies-literature | 2021 Nov
REPOSITORIES: biostudies-literature
Sharma Harish H Nadir M Adnan MA Steeds Richard P RP Doshi Sagar N SN
European heart journal. Case reports 20211026 11
<h4>Background</h4>Annuloplasty failure caused by ring dehiscence can lead to trans-ring and para-ring mitral regurgitation (MR). Transcatheter treatments are available for patients at prohibitive risk of surgery. In patients unsuitable for edge-to-edge repair, valve-in-ring (ViR) transcatheter mitral valve (MV) implantation has been described to treat trans-ring or para-ring jets but not both concurrently.<h4>Case summary</h4>A 78-year-old male presented with severe MR due to dehiscence of a 34 ...[more]