ABSTRACT: Method
Handheld Doppler was used for nursing monitoring from April to October 2020, with anxiety associated with its use reported. We collected information via an anonymous questionnaire to determine the reason for the anxiety. Toccare was subsequently applied for postoperative free flap monitoring by nurses. The protocol involved measuring tissue oxygen saturation by touching the flap with a Toccare probe every 4 hours from 24 to 100 hours postoperatively. Seven months later, a second anonymous questionnaire was conducted, and results were compared.Result
Free deep inferior epigastric artery perforator flaps and anterolateral thigh flaps (n = 5 each) were included. The average tissue oxygen saturation values in the deep inferior epigastric artery perforator and anterolateral thigh flaps were 52.0% and 52.4%, respectively. According to the second questionnaire about Toccare, 7% felt anxious, 62% felt slightly anxious, and 31% did not feel anxious. Toccare was preferred by 89% of nurses who had used both methods.Conclusions
Flap monitoring using Toccare reduced nurses' anxiety. A numerical evaluation method with easy handling and clear doctor call criteria is essential for low-anxiety nursing monitoring.