Project description:Saphenous vein graft aneurysm is an uncommon condition and knowledge about its natural history, and a multi-specialty heart team approach is of utmost importance for better clinical outcomes. This case highlights importance of percutaneous intervention as a viable therapeutic option in the case of saphenous vein graft aneurysms.
Project description:BackgroundAneurysmal dilatation of saphenous vein grafts used for coronary artery bypass grafting is a rare complication. These aneurysms are often large in calibre and pose a risk of rupture with significant haemorrhage.Case summaryWe describe a case whereby a large saphenous vein graft aneurysm is closed percutaneously using a vascular plug to cease flow and promote thrombosis of the aneurysm whilst reconstructing the occluded native artery to negate ischaemia.ConclusionSaphenous vein graft aneurysms following coronary artery bypass graft are rare and late complications. The preferred modality of closure is via percutaneous approach that requires meticulous planning to achieve a good outcome.
Project description:HeartWare is a third-generation continuous flow left ventricular assist device (LVAD) and generates centrifugal pattern of blood flow. In the perioperative setting, interrogating the HeartWare devices is very difficult due to the interference of the Doppler by the impeller frequency and generation of the waterfall artifact. We present a case where using color Doppler a view "inside" the impeller can be seen which corresponds to the centrifugal flow of blood. With time, these images can be looked into in pathological states such as pump thrombosis, to come to a more meaningful conclusion regarding the flow of blood within the centrifugal chamber. Newer technologies are constantly evolving to give us more meaningful insights into the flow of blood within the heart chambers. We believe similar technologies can be applied to see the flow of blood inside the LVAD devices.
Project description:BackgroundMycotic aneurysms of coronary vein grafts are rare and associated with high mortality. They are most commonly a result of surgical or percutaneous intervention, and present with complications including myocardial infarction (MI), infective endocarditis. A recent literature review identified 97 cases of mycotic coronary aneurysms in total.Case summaryA 49-year-old man with a history of coronary artery bypass grafting and septic arthrithis presented with chest pain and fevers and ST elevation on electrocardiogram. Urgent angiogram showed an aneurysmal saphenous vein graft from the PL branch to PDA-no acute intervention was performed due to concern about bacteraemia. Methicillin-sensitive Staphylococcus aureus was grown in urine and blood but no focus of infection was identified. Despite treatment with antibiotics and antiplatelets, the patient returned with evidence of expansion of the SVG aneurysm requiring surgical resection.DiscussionThis case highlights the difficulty in treating acute coronary syndromes involving mycotic aneurysms. Multimodal imaging approaches are useful to identify suspected infection, but false negatives occur. Due to high risk of rupture or haemorrhage, there are limited options for urgent reperfusion in cases of MI with mycotic aneurysm, demonstrating the need for an individualized approach and close follow-up.
Project description:Coronary artery bypass grafting (CABG) surgery maintains an important role in the treatment of coronary artery disease. The huge saphenous vein graft aneurysm (HSVGA) is rare and occurs as a late complication after CABG. Here, we reported a case of HSVGA presenting as non-ST elevation myocardial infarction.
Project description:We report a rare case of sinus of Valsalva aneurysm of both right and left coronary sinus (LCS), with perforation of the LCS opening into the left ventricle. The LCS aneurysm with its perforation was undiagnosed on transthoracic echocardiography emphasizing the role of transesophageal echocardiography in delineating the anatomy.
Project description:PURPOSE:To investigate the hemodynamics characteristics of the "no-touch" saphenous vein graft (SVG) conduits by nicardipine intraluminal administration in vivo experiment. METHODS:A total of 59 consecutive patients were enrolled and underwent a sequential SVG to three non-left anterior descending (LAD) targets with the average runoff ≤2 mm, 30 with "no-touch" harvest technique (group A) and 29 with conventional preparation (group B). The patients were subject to nicardipine intraluminal injection during off-pump coronary artery bypass grafting (CABG) procedure. The intraoperative flow was measured with the ultrasonic transit time flow meter (TTFM), and the graft patency testified by multi-detector computed tomography (MDCT) angiography, respectively. RESULTS:The baseline blood flow was higher in group A than that in group B (p <0.05). However, the increases in blood flow of SVG conduits in group A were lower than those in group B with 19.7 ± 5.9 vs. 35.4 ± 9.2 mL/min, 14.8 ± 5.6 vs. 23.1 ± 6.8 mL/min, 6.6 ± 2.1 vs. 11.2 ± 4.3 mL/min before the first, second, and third anastomose after nicardipine intraluminal administration, respectively (all p <0.01). CONCLUSIONS:No-touch SVGs were associated with higher baseline blood flow and less rises after nicardipine intraluminal administration during off-pump CABG procedure compared with conventional preparation. The no-touch SVGs seemed to be less spastic and well-tolerated on flow dilatation.
Project description:BackgroundDonor-recipient diameter discrepancy can be problematic when using an autologous great saphenous vein graft for internal jugular vein reconstruction. A triple-paneled method of saphenous vein grafting is one solution.Case presentationA 54-year-old man with a thyroid papillary carcinoma underwent total thyroidectomy and bilateral neck dissection. An 8-cm segment of the right internal jugular vein was resected. For reconstruction, a 30-cm segment of the great saphenous vein was harvested and divided into three pieces of equal length. After opening each piece longitudinally, they were sutured together in a side-by-side fashion to create a cylinder that was used to reconstruct the internal jugular vein defect. The graft was patent 10 months after the surgery.ConclusionThe triple-paneled method is feasible for autologous great saphenous vein graft reconstruction of the internal jugular vein.