Unknown

Dataset Information

0

Impact of operators experience on peri-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry.


ABSTRACT:

Background

The Watchman FLX is a device upgrade of the Watchman 2.5 that incorporates several design enhancements intended to simplify left atrial appendage occlusion (LAAO) and improve procedural outcomes. This study compares peri-procedural results of LAAO with Watchman FLX (Boston Scientific, Marlborough, Massachusetts) in centers with varying degrees of experience with the Watchman 2.5 and Watchman FLX.

Methods

Prospective, multicenter, "real-world" registry including consecutive patients undergoing LAAO with the Watchman FLX at 26 Spanish sites (FLX-SPA registry). Implanting centers were classified according to the center's prior experience with the Watchman 2.5. A further division of centers according to whether or not they had performed ≤ 10 or > 10Watchman FLX implants was prespecified at the beginning of the study. Procedural outcomes of institutions stratified according to their experience with the Watchman 2.5 and FLX devices were compared.

Results

359 patients [mean age 75.5 (SD8.1), CHA2DS2-VASc 4.4 (SD1.4), HAS-BLED 3.8(SD0.9)] were included. Global success rate was 98.6%, successful LAAO with the first selected device size was achieved in 95.5% patients and the device was implanted at first attempt in 78.6% cases. There were only 9(2.5%) major peri-procedural complications. No differences in efficacy or safety results according to the centeŕs previous experience with Watchman 2.5 and procedural volume with Watchman FLX existed.

Conclusions

The Watchman FLX attains high procedural success rates with complete LAA sealing in unselected, real-world patients, along with a low incidence of peri-procedural complications, regardless of operatoŕs experience with its previous device iteration or the number of Watchman FLX devices implanted.

SUBMITTER: Cruz-Gonzalez I 

PROVIDER: S-EPMC8728396 | biostudies-literature | 2022 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Impact of operatoŕs experience on <i>peri</i>-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry.

Cruz-González Ignacio I   Torres Saura Francisco F   Trejo-Velasco Blanca B   Antonio Fernández Díaz José J   Fajardo Molina Ricardo R   Del Valle-Fernández Raquel R   Moreno Terribas Gerardo G   Martí Sánchez David D   López-Mínguez José-Ramón JR   Gomez-Blazquez Ivan I   Sanmartin Pena Juan-Carlos JC   Botas Javier J   Martin Lorenzo Pedro P   Palazuelos Jorge J   Albarrán Rincon Ramón R   Mohandes Mohsen M   Rodriguez Entem Felipe-Jose FJ   Martí Gerard G   Valero Ernesto E   Gutiérrez Hipólito H   Amat-Santos Ignacio J IJ   Nombela-Franco Luis L   Salinas Pablo P   Teruel Luis L   Gomez-Hospital Joan-Antoni JA   Arzamendi Dabit D   Torres Sanabria Mario M   Calle Pérez Germán G   Cañadas Pruaño Dolores D   Pérez de Prado Armando A   Benito González Tomás T   Arroyo-Úcar Eduardo E   Estévez-Loureiro Rodrigo R   Caneiro-Queija Berenice B   Ibañez Criado Jose L JL   Ruiz-Nodar Juan M JM  

International journal of cardiology. Heart & vasculature 20211229


<h4>Background</h4>The Watchman FLX is a device upgrade of the Watchman 2.5 that incorporates several design enhancements intended to simplify left atrial appendage occlusion (LAAO) and improve procedural outcomes. This study compares <i>peri</i>-procedural results of LAAO with Watchman FLX (Boston Scientific, Marlborough, Massachusetts) in centers with varying degrees of experience with the Watchman 2.5 and Watchman FLX.<h4>Methods</h4>Prospective, multicenter, "real-world" registry including c  ...[more]

Similar Datasets

| S-EPMC11681556 | biostudies-literature
| S-EPMC10874893 | biostudies-literature
| S-EPMC9867931 | biostudies-literature
| S-EPMC11681346 | biostudies-literature
| S-EPMC10118629 | biostudies-literature
| S-EPMC9904382 | biostudies-literature
| S-EPMC9257454 | biostudies-literature
| S-EPMC10307589 | biostudies-literature
| S-EPMC11782859 | biostudies-literature