Diagnostic performance of electron-density dual-energy CT in detection of cervical disc herniation in comparison with standard gray-scale CT and virtual non-calcium images.


ABSTRACT:

Objectives

To assess the diagnostic performance of dual-energy CT (DECT) with electron-density (ED) image reconstruction compared with standard CT (SC) and virtual non-calcium (VNCa) image CT reconstruction for detecting cervical disc herniation.

Methods

This cross-sectional study was approved by the IRB. We enrolled 64 patients (336 intervertebral discs from C2/3 to C7/T1; mean age, 55 years; 17 women and 47 men) who underwent DECT with spectral reconstruction and 3-T MRI within 2 weeks between January 2018 and June 2020. Four radiologists independently evaluated the first image set of randomized SC, VNCa, and ED images to detect cervical disc herniation. After 8 weeks, the readers re-evaluated the second and the last image sets with an 8-week interval. MRI evaluations performed by two other experienced served as the reference standard. Comparing diagnostic performance between each images set was evaluated by a generalized estimating equation.

Results

A total of 233 cervical disc herniations were noted on MRI. For detecting cervical disc herniation, electron-density images showed higher sensitivity (94% [219/233; 95% CI, 90-97] vs. 76% [177/233; 70-81] vs. 69% [160/233; 62-76]) (p < 0.001) and similar specificity (90% [93/103; 83-95] vs. 89% [92/103; 82-96] vs. 90% [93/103; 83-95]) (p > 0.05) as SC and VNCa images, respectively. Inter-reader agreement for cervical disc herniation calculated among the four readers was moderate for all image sets (κ = 0.558 for ED, κ = 0.422 for SC, and κ = 0.449 for VNCa).

Conclusion

DECT with ED reconstruction can improve cervical disc herniation detection and diagnostic confidence compared with SC and VNCa images.

Key points

• Intervertebral discs with high material density are well visualized on electron-density images obtained from dual-energy CT. • Electron-density images showed much higher sensitivity and diagnostic accuracy than standard CT and virtual non-calcium images for the detection of cervical disc herniation. • Electron-density images can have false-negative results, especially for disc herniation with high signal intensity on T2W images and can show pseudo-disc extrusion at the lower cervical spine.

SUBMITTER: Shim E 

PROVIDER: S-EPMC8782689 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC10500809 | biostudies-literature
| S-EPMC3410361 | biostudies-literature
| S-EPMC8504158 | biostudies-literature
| S-EPMC3401988 | biostudies-literature
| S-EPMC6583408 | biostudies-literature
| S-EPMC8599362 | biostudies-literature
| S-EPMC5531999 | biostudies-other
| S-EPMC3592777 | biostudies-other
| S-EPMC4788436 | biostudies-other