Unknown

Dataset Information

0

Characterization of persistent atrial fibrillation with non-contact charge density mapping and relationship to voltage.


ABSTRACT:

Background

Despite studies using localized high density contact mapping and lower resolution panoramic approaches, the mechanisms that sustain human persistent atrial fibrillation (AF) remain unresolved. Voltage mapping is commonly employed as a surrogate of atrial substrate to guide ablation procedures.

Objective

To study the distribution and temporal stability of activation during persistent AF using a global non-contact charge density approach and compare the findings with bipolar contact mapping.

Methods

Patients undergoing either redo or de novo ablation for persistent AF underwent charge density and voltage mapping to guide the ablation procedure. Offline analysis was performed to measure the temporal stability of three specific charge density activation (CDA) patterns, and the degree of spatial overlap between CDA patterns and low voltage regions.

Results

CDA was observed in patient-specific locations that partially overlapped, comprising local rotational activity (18% of LA), local irregular activity (41% of LA), and focal activity (39% of LA). Local irregular activity had the highest temporal stability. LA voltage was similar in regions with and without CDA.

Conclusion

In persistent AF, CDA patterns appear unrelated to low voltage areas but occur in varying locations with high temporal stability.

SUBMITTER: Lee JMS 

PROVIDER: S-EPMC8851595 | biostudies-literature | 2022 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Characterization of persistent atrial fibrillation with non-contact charge density mapping and relationship to voltage.

Lee Justin M S JMS   Nelson Thomas A TA   Clayton Richard H RH   Kelland Nicholas F NF  

Journal of arrhythmia 20211123 1


<h4>Background</h4>Despite studies using localized high density contact mapping and lower resolution panoramic approaches, the mechanisms that sustain human persistent atrial fibrillation (AF) remain unresolved. Voltage mapping is commonly employed as a surrogate of atrial substrate to guide ablation procedures.<h4>Objective</h4>To study the distribution and temporal stability of activation during persistent AF using a global non-contact charge density approach and compare the findings with bipo  ...[more]

Similar Datasets

| S-EPMC7411208 | biostudies-literature
| S-EPMC9622778 | biostudies-literature
| S-EPMC9238707 | biostudies-literature
| S-EPMC7593698 | biostudies-literature
| S-EPMC9735148 | biostudies-literature
| S-EPMC9145946 | biostudies-literature
| S-EPMC9075313 | biostudies-literature
| S-EPMC5524032 | biostudies-other
| S-EPMC9071092 | biostudies-literature