Unknown

Dataset Information

0

Less Fluctuation in Hemodynamics of the Wide-Awake Local Anesthesia No Tourniquet Technique Than General Anesthesia in Distal Radius Plating Surgery: A Prospective Case-Control Study.


ABSTRACT: This prospective case-control study aimed to compare the intraoperative hemodynamic changes between the wide-awake local anesthesia no tourniquet (WALANT) technique and general anesthesia (GA) in patients undergoing distal radius plating surgery. Forty adults with distal radius fractures underwent plating surgery via the WALANT technique (20 patients) or GA (20 patients). Mean arterial pressure (MAP) and heart rate were recorded. Intraoperative pain intensity was measured using the visual analog scale (VAS) for pain in the WALANT group. The measures of hemodynamics and VAS were recorded at seven-time points perioperatively. The VAS score decreased significantly compared with the preoperative status in the WALANT group for most of the intraoperative period except during injections of local anesthetics and fracture reduction. The intraoperative MAP in the WALANT group showed no significant change during the perioperative period. In addition, the WALANT group showed fewer perioperative MAP fluctuations than the GA group (p < 0.05). The reduction and plating quality were similar between the two groups. WALANT provided a feasible technique with less fluctuation in hemodynamic status. With gentle manipulation of the fracture reduction, distal radius plating surgery using the WALANT technique is a well-tolerated surgical procedure and shows similar reduction and plating quality to GA.

SUBMITTER: Liu WC 

PROVIDER: S-EPMC8875852 | biostudies-literature | 2022 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Less Fluctuation in Hemodynamics of the Wide-Awake Local Anesthesia No Tourniquet Technique Than General Anesthesia in Distal Radius Plating Surgery: A Prospective Case-Control Study.

Liu Wen-Chih WC   Lu I-Cheng IC   Chang Chung-Chia CC   Chen Chih-Ting CT   Chen Chung-Hwan CH   Shih Chia-Lung CL   Fu Yin-Chih YC   Jupiter Jesse Bernard JB  

Journal of clinical medicine 20220221 4


This prospective case-control study aimed to compare the intraoperative hemodynamic changes between the wide-awake local anesthesia no tourniquet (WALANT) technique and general anesthesia (GA) in patients undergoing distal radius plating surgery. Forty adults with distal radius fractures underwent plating surgery via the WALANT technique (20 patients) or GA (20 patients). Mean arterial pressure (MAP) and heart rate were recorded. Intraoperative pain intensity was measured using the visual analog  ...[more]

Similar Datasets

| S-EPMC10546761 | biostudies-literature
| S-EPMC8991627 | biostudies-literature
| S-EPMC9605417 | biostudies-literature
| S-EPMC9678723 | biostudies-literature
| S-EPMC7468561 | biostudies-literature
| S-EPMC9678692 | biostudies-literature
| S-EPMC9678648 | biostudies-literature
| S-EPMC9678725 | biostudies-literature
| S-EPMC9678647 | biostudies-literature
| S-EPMC10039231 | biostudies-literature